Reliability data
Test
Standard
Test conditions
R
25
/R
25
(typical)
Remarks
Storage in
dry heat
IEC
60068-2-2
Storage at upper
category temperature
T: 125
°
C
t: 1000 h
< 1%
No visible
damage
Storage in damp
heat, steady state
IEC
60068-2-78
Temperature of air: 40
°
C
Relative humidity of air: 93%
Duration: 56 days
< 1%
No visible
damage
Rapid temperature
cycling
IEC
60068-2-14
Lower test temperature:

55
°
C
Upper test temperature: 125
°
C
Number of cycles: 10
< 0.5%
No visible
damage
Endurance
P
max
: 150 mW
t: 1000 h
< 1%
No visible
damage
Long-term stability
(empirical value)
Temperature: 70
°
C
t: 10000 h
< 2%
No visible
damage