Bauser BZ/IZ 12-24V/DC BZ/IZ Digital counter - Twin technology Assembly dimensions 45 x 22 mm 3840.2.1.1.1.2 Twin3 数据表

产品代码
3840.2.1.1.1.2 Twin3
下载
页码 11
14
Time or pulse counters for DIN-rail mounting, 2 displays,
multi voltage 12 - 150 V DC and 24 - 240 V AC,
overall height 60 mm
type 672.6.X.X.X.X
drawings
wiring diagram
Digital time or pulse counters with high visibility 7-digit-LC-display. You decide, which
value should be indicated by this double counter. Two times time or pulses or even one
time and one pulse indication. The heart of these counters is a new ASIC-component,
which has been developed by BAUSER. This component enables a voltage range of 12 -
150 V DC and 24 - 240 V AC in just one unit. The single counters are available without
or with a manual reset and with common or separate input.
Order specifications type range 672.6.X.X.X.X
y
Digital time
and pulse counters
plastic light grey RAL 7035
LC-display, 7 digits (0.1h resolution for hour counter)
5 mm
12 V DC - 150 V DC and 24 V AC - 240 V AC ±10 % (in one unit)
50/60 Hz
100 μA - 3 mA
approx. 120 kOhm (Count, Reset)
IP65 (without reset button)
IP40 (with reset button), screw IP20
-10 °C bis +70 °C
-40 °C bis +80 °C
Terminal Blocks (lift principle) with Philips-Head-Screw (+/- screw) in
combination with slotted screw with 3 mm screwdriver size, 0-2.5 mm
2
fine wire or 0-4 mm
2
single wire
0,5 Nm
1 g (10...500 Hz) according to EN 60068-2-34
30 g (18 ms) according to EN 60068-2-27
25 g (6 ms) according to EN 60068-2-29
EN 55011, EN 61000-6-2
EN 61010, protection class II
, UL, cUL
without, electrical or manual and electrical (sunk button, for example
utilisable with ball point pen)
approx. 75 g
maximum 10 Hz for AC signal voltage
optionally higher counting frequency at DC-version
EEPROM (min. 25 years)
snap-on fixing for DIN-rail according DIN EN 50022
housing:
indication:
character height:
operating voltage (Ub):
frequency:
current consumption:
input resistance:
protection (front):
ambient temperature:
stocking temperature:
electrical connection:
max. torque:
vibration resistance:
shock resistance:
EMC:
industrial norm:
approval:
reset:
weight:
counting frequency/
pulse counter:
data storage:
fixing:
6 7 2 . 6 . X . X . X . X
1 without reset
2 with manual reset
1 hour counter
2 pulse counter
1 without reset
2 with manual reset
1 hour counter
2 pulse counter
Configuration
counter 2
Configuration
counter 1
Technical specifications:
1 = DC “+“ or AC
2 = DC “–“ or AC
3 = Time or pulse
counter input,
counterr 1
4 = Time or pulse
counter input,
counterr 2
Counter 1
Counter 2
Reset Z. 1
(Option)
Reset Z. 2
(Option)