Bender VMD4105-D-2 B93010045 数据表
产品代码
B93010045
55
8. Technical data VMD460-NA
( )* = factory setting
Insulation coordination acc. to IEC 60664-1/IEC 60664-3
Rated insulation voltage ....................................................................................................................................... 400 V
Overvoltage category.....................................................................................................................................................III
Rated impulse voltage/pollution degree ..............................................................................................................6 kV/2
Protective separation (reinforced insulation) between.................(A1, A2) - (L1, L2, L3, N) - (11, 12, 14, 21, 22, 24)
Rated insulation voltage ....................................................................................................................................... 400 V
Overvoltage category.....................................................................................................................................................III
Rated impulse voltage/pollution degree ..............................................................................................................6 kV/2
Protective separation (reinforced insulation) between.................(A1, A2) - (L1, L2, L3, N) - (11, 12, 14, 21, 22, 24)
(D1, D2, D3, D4, DG1/2, DG3/4, RTG, RT1)-(A1, A2, L1, L2, L3, N)
Voltage test according to IEC 61010-1:
(N, L1, L2, L3) - (A1, A2), (11, 12, 14, 21, 22, 24) ............................................................................................ 3.32 kV
(N, L1, L2, L3) - (A1, A2), (11, 12, 14, 21, 22, 24) ............................................................................................ 3.32 kV
Supply voltage
Rated supply voltage
Rated supply voltage
U
s
................................................................................................................ AC/DC 100…240 V
....................................................................................................................................................................DC / 50/60 Hz
Operating range
U
s
...........................................................................................................................AC/DC 75…300 V
............................................................................................................................................................... DC / 40…70 Hz
Power consumption at AC 230 V .....................................................................................................< 7,5 VA /< 3,5 W
max. ................................................................................................................9 VA / 3,5 W
Measuring circuit
Nominal system voltage
Nominal system voltage
U
n
(r.m.s. value) (L-N) ..................................................................................... AC 0…300 V
Nominal system voltage
U
n
(r.m.s. value) (L-L) ..................................................................................... AC 0…520 V
Rated frequency
f
n
(
U
n
> 20 V) ................................................................................................................... 45…65 Hz
Response values
Type of distribution system .............................................................................................................. 1 AC: 230 V, 50 Hz
Type of distribution system .............................................................................................................. 1 AC: 230 V, 50 Hz
................................................................................................................................................3(N)AC: 400/230 V, 50 Hz
Relative uncertainty, voltage .........................................................................................................U ≤ 280 V: ≤ ±1 %
............................................................................................................................................................. U > 280 V: ±3 %
Resolution of setting voltage.................................................................................................................................... 1 %
Rated frequency ..................................................................................................................................................... 50 Hz
Relative uncertainty, frequency...................................................................................................................... ≤ ±0.1 %
Resolution of setting
Rated frequency ..................................................................................................................................................... 50 Hz
Relative uncertainty, frequency...................................................................................................................... ≤ ±0.1 %
Resolution of setting
f ......................................................................................................................................... 0.05 Hz