Kuebler Kübler CODIX 529 Process display Codix 529 Assembly dimensions 45 x 22 mm 6.529.012.300 数据表

产品代码
6.529.012.300
下载
页码 7
8
- Subject to change without pr
ior notice -
C
CO
OD
DIIX
X  5
52
29
9
Ordering code: 6.529.012.300
Operating instructions
Digital display with analogue inputs
• 5digit digital display with analogue inputs
• LED-Display with 8 mm high characters and
very high luminosity
• Display range -19999..99999 with leading zero
blanking
• Programming of functions and operating
parameters via the setting keys. During pro-
gramming the display guides the user with text
prompts.
• Programmable features:
Range
Max. value display yes/no
Max. value reset yes/no
Min. value display yes/no
Min. value reset yes/no
Decimal point
Min. input signal
Displayed value at min. input signal
Max. input signal
Displayed value at max. input signal
2. Inputs
LATCH (Connect 4)
Static input to freeze the displayed value.
If this input (pnp) is supplied with 
4 ... 30 V DC the actual value is frozen
until the input is released or the signal
level gets below 2 V DC. The calculating of
max. and min. value is not affected.
CURRENT INPUT (Connect 5)
Analogue current input with reverse con-
nection protection and current limitation to
max. 50 mA. Connect the signal line with
the analogue signal with this input.
CAUTION: To prevent interfering signals
caused by the supply voltage, this input is
isolated from the supply voltage. Connect
the signal line with the Signal to the ana-
logue reference input.
ANLOGUE REFERENCE INPUT
(Connect 6)
If no isolation between measuring circuit
and supply voltage is necessary, connect
pin 2 or 3 to this input
VOLTAGE INPUT
(Connect 7)
Analogue voltage input. Connect the sig-
nal line with the analogue signal with
this input. In case of reverse connection,
the display shows „Err4“.
CAUTION: To prevent interfering signals
caused by the supply voltage, this input is
isolated from the supply voltage. Connect
the signal line with the Signal to ana-
logue reference input.
1. Description