- Instructions for use - 
 
 
 
 
Introduction 
Thank  you  for  deciding  for  the  blood 
pressure  monitor  SC  2100  from  SCALA 
Electronic GmbH. To be able to utilise all 
advantages of the blood pressure monitor 
to  the  fullest,  you  should  carefully  read 
these  instructions  before  using  the 
monitor.  Keep  the  instruction  leaflet  in  a 
safe place. 
 
Safety instructions 
The  blood  pressure  monitor  SC  2100 
enables  you  to  monitor  your  blood 
pressure  regularly.  However,  you  should 
never  change  the  treatment  which  your 
doctor has prescribed  
Self-measurement means monitoring, 
it does not imply diagnosis or 
treatment. 
Discuss unusual values with your doctor.  
Do not change the medication 
prescribed by your doctor. 
The heart rate is not a useful indicator of 
the frequency of a cardiac pace maker. 
 
Features of the SC 2100 

 The  monitor  automatically  detects  the 
required  inflation  pressure,  i.e.,  the  „P“ 
(for  pump)  remains  displayed  until  the 
required  inflation  pressure  for  a  safe 
measurement is obtained. 

 WHO-Interpretation  of  blood  pressure 
readings  with  colored  band
 
(See 
description at page 7). 

 The device has 85 memory locations. 

 If  your  heartbeat  is  not  regular 
(irregular),  the  “            “    icon  appears  in 
the LC display. 

 The  date  and  time  are  displayed  and 
stored  together  with  every  blood 
pressure value. 

 The cuff is suitable for upper arms with 
a  circumference  between  22  and  32 
cm. 
 
 
- 2 - 
 
Preparing the monitor for 
measurement / changing battery 
Insert  the  supplied  batteriy  in  the  battery 
compartment at the rear side of the blood 
pressure monitor as shown. Use only an 
alkali battery (LR03)
.  
If the battery is depleted, the battery icon 
  is  displayed  in the  top  left  corner  of 
the LC display. The battery needs urgent 
replacement because you cannot use the 
monitor with depleted battery. 
 
Device description 
 
 
 
 
 
 
 
 
 
 
 
 
The LC display 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
- 3 - 
Setting the clock  
Switch  off  the  device  and  hold  the  TIME 
button  pressed  for  approx.  2  seconds. 
The  year  20XX  blinks  in  the  top  left 
corner of the display.
  
Set the year with the ON/OFF button. 
When  the  correct  year  is  set,  press  the 
TIME  button  again.  Now  the  1  blinks  in 
the  top  left  corner  of  the  LCD.  It  stands 
for the month.  
Set the month with the ON/OFF button. 
Another  press  of  the  TIME  button  sets 
another  1  blinking.  It  stands  for  the  first 
day in the month.  
Set the day with the ON/OFF button. 
Another  press  of  the  TIME  button  takes 
you to the clock setting – the hours blink. 
As b efore, set the clock with the ON/OFF 
button.
  
Pressing  the  TIME  button  advances  to 
the minutes setting.  
Set the minutes with the ON/OFF button. 
A  final  press  of  the  TIME  button 
completes  the  setting  of  the  date  and 
time. 
 
How  to  obtain  correct  measuring 
results? 
To  obtain  correct  readings,  measure  the 
blood  pressure  always  under  the  same  
conditions, at rest, not under the effect of 
alcohol, not during meals, not after heavy 
physical  or  mental  stress.  If  possible,  sit 
down at a table for the measurement. 
 
The blood pressure measurement 
Put the cuff around your left upper arm in 
such  a  way  that  the  tube  is  directed 
towards  the  bend  of  the  elbow,  with  the 
lower  cuff  edge  ending  about  2-3  cm 
above the bend of the elbow.  
 
 
 
 
 
- 4 - 
 
 
2-3 cm 
 
 
 
 
 
The cuff should be reasonably tight. 
 
Switch  the  device  on  and  off  at  thee 
ON/OFF  button.  The  display  shows  ”P” 
and  ”0”.  Start  inflating  the  cuff  with  the 
manual pump.  
 
CAUTION: 
Pumpe until the”P” disappears 
from the display. 
 
Then  the  measurement  starts.  Deflation 
is automatic.  
 
CAUTION:  Setn  the  deflation  rate  at 
the  air  deflation  valve  on  the  rear  of 
the  monitor  to  approx.  3  to  4  mmHg 
per  second.  Turning  out  the  deflation 
valve  reduces  the  deflation  rate. This 
setting is only required during the first 
measurement – provided the deflation 
rate is not changed.  
 
 
 
 
 
 
 
 
 
 
 
 
After  about  3  seconds  a  heart  starts 
blinking  in    the  display  (heart  rate 
identified).  
The  cuff  pressure  is  reduced  further  and 
is displayed continuously. If the diastoclic 
(öower) blood pressure is detected, the  
 
- 5 -