Atmel Xplained Evaluation Board AT32UC3A3-XPLD AT32UC3A3-XPLD 数据表

产品代码
AT32UC3A3-XPLD
下载
页码 1021
75
32072H–AVR32–10/2012
AT32UC3A3
7.6.17
BOD Control Register
Name:
BOD
Access Type:
Read/Write
Offset:
0xD0
Reset Value:
0x00000000
• KEY: Register Write protection
This field must be written twice, first with key value 0x55, then 0xAA, for a write operation to have an effect.
• FCD: BOD Fuse calibration done 
Set to 1 when CTRL, HYST and LEVEL fields has been updated by the Flash fuses after power-on reset or Flash fuses update
If one, the CTRL, HYST and LEVEL values will not be updated again by Flash fuses
Can be cleared to allow subsequent overwriting of the value by Flash fuses
• CTRL: BOD Control 
0: BOD is off
1: BOD is enabled and can reset the chip
2: BOD is enabled and but cannot reset the chip. Only interrupt will be sent to interrupt controller, if enabled in the IMR register.
3: BOD is off
• HYST: BOD Hysteresis 
0: No hysteresis
1: Hysteresis On
• LEVEL: BOD Level 
This field sets the triggering threshold of the BOD. See Electrical Characteristics for actual voltage levels.
Note that any change to the LEVEL field of the BOD register should be done with the BOD deactivated to avoid spurious reset 
or interrupt.
31
30
29
28
27
26
25
24
KEY
23
22
21
20
19
18
17
16
-
-
-
-
-
-
-
FCD
15
14
13
12
11
10
9
8
-
-
-
-
-
-
CTRL
7
6
5
4
3
2
1
0
-
HYST
LEVEL