5.3 Special functions
LOGO!Soft Comfort Online Help
Operating Instructions, 06/2014
Operating Instructions, 06/2014
237
Short description
The output is controlled by means of a configurable on/off date. The function supports any
combination of weekdays.
Connection
Description
Parameters No1,
No2, No3
At the No1, No2, No3 (Cam) parameters you set the on- and off-time triggers for
each cam of the weekly timer. For each Cam you specify the day of the week
and the time of day for the on- and off-times.
Par
You specify whether the timer pulses on for one cycle when activated and is then
reset. The pulse parameter applies to all three cams.
Output Q
Q is set when the configured cam is actuated.
Timing diagram (three practical examples)
Description of the function
Each weekly timer is equipped with three cams. You can configure a time hysteresis for each
individual cam. At the cams you set the on- and off-hysteresis. The weekly timer sets the
output at a certain time, provided it is not already set.
The weekly timer resets the output at the off-time if you configured an off-time, or at the end
The weekly timer resets the output at the off-time if you configured an off-time, or at the end
of the cycle if you specified a pulse output. A conflict is generated in the weekly timer when
the on-time and the off-time at another cam are identical. In this case, cam 3 takes priority
over cam 2, while cam 2 takes priority over cam 1.
The switching status of the weekly timer is determined by the status at the No1, No2 and
The switching status of the weekly timer is determined by the status at the No1, No2 and
No3 cams.
On-times
The on-time is any time between 00:00 h and 23:59 h. You can also configure the on-time to
be a pulse signal. The timer block will be activated at the specified time for one cycle and
then the output is reset. The off-time is disabled in this case as it is not applicable.
Special characteristics to note when configuring
The block properties window offers a tab for each one of the three cams. Here you can set
the day of the week for each cam. Each tab offers you in addition an option of defining the