Faber Kabel 051452, Cable, , Black Sheath 051452 数据表
产品代码
051452
DBL_H05RNH2F.PDF Issue 26.09.2014 Klaus Faber AG, 66113 Saarbrücken, Lebacher Str. 152-156, Tel.: (0681) 9711-0, FAX: - 289
Flat light-chain cable H05RNH2-
F acc. to EN 50525-2-82
conductor material:
bare copper
conductor construction:
fine stranded, class 5
insulation:
rubber (EPR) EI4
sheathing material:
rubber (CR) EM2
flame retardant:
VDE 0482-332-1-2/IEC 60332-1
maximum temperature at
conductor:
60 °C
max. operating temperature,
fixed:
-25 - +60 °C
nominal voltage Uo:
300 V
nominal voltage U:
500 V
core identification:
colours acc. VDE 0293 (HD308)
Application: Cable for dry and wet rooms as well as outdoor for temporary installation of fairy lights.
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
Table: Technical characteristics H05RNH2-F
p/n
part name
R
l
.
[Ω/km]
b
.
[mm]
h
.
[mm]
Cu
.
[kg/km]
G
.
[kg]
050411
H05RNH2-F 02X1,5 GN
Illuminationsleitung
Illuminationsleitung
13,3
14
6
28,8
145
051452
H05RNH2-F 02X2,5 SW
Illuminationsleitung
Illuminationsleitung
48
195
Rl
conductor resistance
b
width of (flat) cable
h
hight of (flat) cable
Cu
copper
G
weight