Bourns PTC fuse Current I(H) 0.13 A 250 V (L x W x H) 7.4 x 6.6 x 3.43 mm MF-SM013/250V-2 1 pc(s) MF-SM013/250V-2 数据表

产品代码
MF-SM013/250V-2
下载
页码 4
Features
  Surface mount devices
  High voltage surge capabilities 
  Binned and sorted resistance ranges
  Assists in meeting ITU K.20/K.21 
 specifi cations
 RoHS compliant*
 Agency recognition: 
Applications
Used as a secondary overcurrent protection 
device in:
  Customer Premise Equipment (CPE)
 Central Offi ce (CO)
  Subscriber Line Interface Cards (SLIC)
  
 
MF-SM013/250 - Telecom PTC Resettable Fuses
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. 
 Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
*RoHS COMPLIANT
Environmental Characteristics
Operating Temperature ......................................... -45 °C to +85 °C
Maximum Device Surface Temperature 
 in 
Tripped 
State 
................................................ 125 
°C
Passive Aging ....................................................... +85 °C, 1000 hours ............................................... ±2 % typical resistance change
   
+60 °C, 1000 hours ............................................... ±3 % typical resistance change
Humidity Aging...................................................... +85 °C, 85 % R.H. 500 hours ............................... ±3 % typical resistance change
Thermal Shock ..................................................... MIL-STD-202F, Method 107G, .............................. ±10 % typical resistance change
   .......................................................................... +125 °C to -55 °C,10 times ................................... ±15 % typical resistance change
Solvent Resistance ............................................... MIL-STD-202, Method 215B ................................. No change
Lead Solerability ................................................... ANSI/J-STD-002
Flammability ......................................................... IEC 695-2-2 .......................................................... No Flame for 60 secs.
Vibration ............................................................... MIL-STD-883C, Method 2007.1, Condition A ....... No change
  Test Procedures And Requirements For Model MF-SM013/250 Series
 
Test 
Test Conditions 
Accept/Reject Criteria
Visual/Mech. .................................................... Verify dimensions and materials .......................Per MF physical description
Resistance ....................................................... In still air @ 23 °C .............................................Rmin 
≤ R ≤ Rmax
Time to Trip ...................................................... At specifi ed current, Vmax, 23 °C .....................T 
≤ max. time to trip (seconds)
Hold Current .................................................... 30 min. at Ihold .................................................No trip
Trip Cycle Life .................................................. Vmax, Imax, 100 cycles ....................................No arcing or burning
Trip Endurance ................................................ Vmax, 48 hours .................................................No arcing or burning
Solderability ..................................................... MIL-STD-202F, Method 208F ...........................95 % min. coverage
UL File Number ............................................... E 174545S
CSA File Number ............................................. CA 110338
TÜV File Number ............................................. R2057213
Electrical Characteristics
Model
Max. 
Operating 
Voltage
 Max. Interrupt 
Ratings
Hold 
Current
Initial
Resistance
One Hour 
Post-Trip
Resistance
Tripped
Power
Dissipation
Volts
(V)
Volts
(V)
Amps 
(A)
Amps
at 23 °C
Ohms
at 23 °C
Ohms
at 23 °C
Ohms
at 23 °C
Watts
at 23 °C
Max.
Max.
IH
Min.
Max.
Max.
Typ.
MF-SM013/250-2
60
250
3.0
0.13
6.5
12.0
20.0
3.3
MF-SM013/250-A-2
60
250
3.0
0.13
6.5
9.0
20.0
3.3
MF-SM013/250-B-2
60
250
3.0
0.13
9.0
12.0
20.0
3.3
MF-SM013/250-C-2
60
250
3.0
0.13
7.0
10.0
20.0
3.3
Thermal Derating Chart - Ihold/ Itrip (Amps)
Model
Ambient Operating Temperature
-40 ºC
-20 ºC
0 ºC
23 ºC
40 ºC
50 ºC
60 ºC
70 ºC
85 ºC
MF-SM013/250-2 
0.21 / 0.42
0.18 / 0.37
0.16 / 0.31
0.13 / 0.26
0.10 / 0.23
0.09 / 0.18
0.08 / 0.15
0.07 / 0.12
0.05 / 0.10
MF-SM013/250-A-2
0.21 / 0.42
0.18 / 0.37
0.16 / 0.31
0.13 / 0.26
0.10 / 0.23
0.09 / 0.18
0.08 / 0.15
0.07 / 0.12
0.05 / 0.10
MF-SM013/250-B-2
0.21 / 0.42
0.18 / 0.37
0.16 / 0.31
0.13 / 0.26
0.10 / 0.23
0.09 / 0.18
0.08 / 0.15
0.07 / 0.12
0.05 / 0.10
MF-SM013/250-C-2
0.21 / 0.42
0.18 / 0.37
0.16 / 0.31
0.13 / 0.26
0.10 / 0.23
0.09 / 0.18
0.08 / 0.15
0.07 / 0.12
0.05 / 0.10