Fanox U3S-3x400V AC U3S-3x400V AC U3S-3x400V AC 数据表

产品代码
U3S-3x400V AC
下载
页码 1
22
U1 D                  U1 M
U3 S
Voltage & frequency monitoring relays
Single-phase voltage relay
Three-phase voltage relay
• Minimum and maximum thresholds adjustable
(two potentiometers).
• U1D: Tripping time delay adjustable. Instantaneous
reset. Protects equipment such as digital
instruments or electrical equipment from voltage
variations in the network.
• U1M: Tripping time delay adjustable. Fixed reset
delay (5 minutes). Suitable for single phase air
conditioning.
• Protects three-phase installations against voltage
variations between phases, incorrect sequence of
phases and phase loss.
• Minimum and maximum thresholds adjustable
(two potentiometers).
• 
Tripping time delay adjustable (two
potentiometers).
• Model U3S-420 is valid for 400 and 440 nominal V.
Protections
Models
Frequency
Maximum threshold 
V / Hz
Minimum threshold
V / Hz
Code no.
Characteristics
Type of supply to be monitored
Auxiliary supply ±10%
Accuracy
Trip time delay (TD)
Reset time delay (RD)
Reset mode
Hysteresis
Signalling LED’s
Output contacts
Switching power
Terminals: Max. section / Screw torque
Power consumption
Protection degree / weight
Storage / operation temperature
U1D-24D U1D-115 U1D-230
DC
50/60 Hz 50/60 Hz
23-28
105-135 215-275
19-25
90-120
160-230
12028
12026
12027
U1M-24D U1M-115 U1M-230
DC
50/60 Hz 50/60 Hz
23-28
105-135 215-275
19-25
90-120
160-230
12080
12081
12082
U3S-230
U3S-420
50/60 Hz
50/60 Hz
210-290
380-500
185-230
350-430
12071
12070
Single phase
Self-powered
+4% -1%;      +1% -4%
0,1 to 6s (±20%) for
U1D: No  / U1M: fix 5 min.
Automatic
4% of the nominal voltage
3 LED’s: ON +        +
1 relay with 1 change-over NO - NC
I
th
: 5A; AC15 - 250V - 2A; DC13 - 30V - 2A
2,5 mm
2
, No. 22 - 12AWG / 20Ncm, 1.8 LB - IN
3 VA (115 Vac) - 7 VA (230 Vac) - 0,7W (24 Vdc)
IP20 / 0,11 kg
-30°C +70 °C / -15°C +60°C
Three phase
Self-powered
+4% -1%;      +1% -4%
0,1 to 6s (±20%) for
-
Automatic
4% of the nominal voltage
4 LED’s: ON +        +        +
1 relay with 1 change-over NO - NC
I
th
: 5A; AC15 - 250V - 2A; DC13 - 30V - 2A
2,5 mm
2
, No. 22 - 12AWG / 20Ncm, 1.8 LB - IN
7,5 VA (230 Vac) - 11 VA (400 Vac)
IP20 / 0,12 kg
-30°C +70 °C / -15°C +60°C
Phase imbalance or phase loss
Phase sequence
Overvoltage
Undervoltage
Loss of neutral
Frequency variation
Protections
N
For dimensions see page 35.
H
TD
U
>
U
<
U
<
H
U
>
U
<
TD
TD
TD
11
14
12
11
14
12
RD
RD
RD
U
>
U
<
U
<
1
t
LED's
RELÉ
LED's
RELÉ
U1-D
U1-M
1
Si TD>t
RST
SRT
H
H
RELÉ
U
>
U
<
11
14
12
LED's
TD
U
>
U
<
U
>
L 1-2
L 2-3
L 3-1
U
<
TD
TD
Hz 
RELAY
RELAY
RELAY
If TD>t
ingles interior 2008:ingles interior 2005  13/5/08  15:32  Página 22