Specification Update
V2.
BR0# Maximum Hold Time Specification Change
The BR0# maximum hold time has changed to 2 BCLKs. This change will be shown in the “System
Bus AC Specifications (Reset Conditions)” table and “System Bus Reset and Configuration Timings”
figure of the Mobile Intel
Bus AC Specifications (Reset Conditions)” table and “System Bus Reset and Configuration Timings”
figure of the Mobile Intel
®
Celeron
®
Processor on .13 Micron Process in Micro-FCPGA Package
Datasheet. This change will be incorporated in the next revision of the datasheet.
Currently it states:
Table 21. System Bus AC Specifications (Reset Conditions)
T# Parameter
Min
Max
Unit
Figure
Notes
T45: Reset Configuration Signals (A[31:3]#, BR0# INIT#, SMI#)
Setup Time
Setup Time
4
BCLKs 13 1
T46: Reset Configuration Signals (A[31:3]#, BR0# INIT#, SMI#)
Hold Time
Hold Time
2 20
BCLKs 13
2
NOTES:
1.
Before the deassertion of RESET#.
2.
After clock that deasserts RESET#.
It should state:
Table 21. System Bus AC Specifications (Reset Conditions)
T#
Parameter
Min Max Unit Figure Notes
T45: Reset Configuration Signals (A[31:3]#, BR0# INIT#,
SMI#) Setup Time
SMI#) Setup Time
4
BCLKs
13 1
T46:Reset Configuration Signals (A[31:3]#,INIT#, SMI#)
Hold Time
Hold Time
2 20
BCLKs 13
2
T47: Reset Configuration Signal BR0# Hold Time
2
2
BCLKs
13
2
NOTES:
1.
Before the deassertion of RESET#.
2.
After clock that deasserts RESET#.