Phoenix Contact Reversing load relay ELR W1/ 2-24DC 2963598 2963598 数据表

产品代码
2963598
下载
页码 6
Nov 9, 2013    2 / 6
Technical data
Input data
Protective circuit
Protection against polarity reversal
Protective circuit
Surge protection
Surge voltage protection
> 33 V DC
Typical response time
200 µs
Status display
LED yellow, forward running (R), LED yellow, reverse running (L)
Current consumption
3 mA
Switchover time R
L
/L
L
 (turn-on time)
80 ms
Output data
Output name
DC output
Nominal output voltage range
10 V DC ... 30 V DC
Load current
2 A (Mounted in rows with zero spacing)
Quiescent current
approx. 7 mA (When switched off)
Type of protection
Protection against polarity reversal
Type of protection
Surge protection
Surge voltage protection
> 33 V DC
Operating voltage display
Green LED
Current limitation at short-circuits
15 A
Connection data
Connection method
Screw connection
Stripping length
8 mm
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
6 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
4 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
10
Screw thread
M3
General
Test voltage input/output
2.5 kV AC
Mounting position
Vertical (horizontal DIN rail)
Assembly instructions
Any
Operating mode
100% operating factor
Name
Air and creepage distances between the power circuits
Standards/regulations
EN 50178
Standards/regulations
Basic insulation
Pollution degree
2
Surge voltage category
III