Figaro TGS-5342 gas sensor (W x H) 27.9 mm x 16,9 mm TGS-5342 数据表

产品代码
TGS-5342
下载
页码 2
PRODUCT INFORMATION
Applications:
Features:
TGS 5342 - 
for the detection of Carbon Monoxide
The figure below represents typical sensitivity characteristics, 
all data having been gathered at standard test conditions (see 
reverse side of this sheet).  The Y-axis shows theoutput current 
of the sensor (Iout/µA) in each gas. Output current is linear 
to CO concentration, with a deviation of less than ±5% in the 
range of 0~500ppm.
The figure below represents typical temperature dependency 
characteristics.  The Y-axis shows the sensor output ratio (I/Io) 
as defined below. The linear relationship between I/Io and CO 
concentration is constant regardless of the CO concentration 
range.
 
I = Sensor output current in 400ppm of CO at various 
 
   
temperatures
 
Io = Sensor output current in 400ppm at 20˚C/50%RH
* Residential and commercial CO detectors
* CO monitors for industrial applications
* Ventilation control for indoor parking garages
* Recreational vehicle CO detectors
* Marine CO detectors
* Fire detection
Figaro’s 
TGS5342 is a battery operable electrochemical sensor which offer several 
advantages over traditional electrochemical sensors. Its electrolyte is environmentally 
friendly, it poses no risk of electrolyte leakage, can detect concentrations as high 
as 1% CO, operates in a range from -40˚ and +70˚C, and it has lower sensitivity to 
interferant gases. With a long life, good long term stability, and high accuracy, this 
sensor is the ideal choice for CO detectors with digital display. OEM customers will 
find individual sensors data printed on each sensor in bar code from, enabling users 
to skip the costly gas calibration process and allowing for individual sensor tracking. 
The length of TGS5342 is 60% of the TGS5042.
* Battery operable
* Compact size
* High repeatability/selectivity to CO
* Linear relationship between CO gas 
concentration and sensor output
* Simple calibration
* Long life
* UL recognized component
* Meets UL2034, EN50291, and RoHS
 requirements
Temperature Dependency:
Sensitivity Characteristics:
IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY 
RECOMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET 
GASES ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS 
NOT BEEN SPECIFICALLY TESTED BY FIGARO.
-0.2
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0
200
400
600
800
1000
CO
H2
Iout(µA)
Gas concentration (ppm)
0.0
0.5
1.0
1.5
2.0
-40
-20
0
20
40
60
I/Io
Temperature (˚C)