Panasonic Microswitch 30 Vdc 0.1 A 1 x On/(On) ASQ11510J momentary 1 pc(s) ASQ11510J 数据表

产品代码
ASQ11510J
下载
页码 10
ASQ1
6. Wire leads left side type: Mounting hole 3mm, standard type
mm General tolerance: ±0.25
NOTES
1.9 dia.
8.4
±0.2
5.4
±0.15
C 0.3
R 0.5
R 0.5
TTP (5.9)
OP (NO) 8.4
±
0.3
OP (NC) 8.7
±
0.3
FP 9.2 MAX.
5.9
3.7
1.4 dia.
4.5
5.2
5.0
±2
4.3
8.3
±0.1
5.1
3.2
±0.1
2.7
5.4
13.3
3.0
+0.1
−0
300
±10
2.4
R 0.5
3.0
+0
−0.1
 dia.
∗ Wire lead thickness
Wire lead color
:
:
:
:
0.3mm
2
COM
NC
NO
····
·······
·······
Black
Red
White
1. Soldering conditions
The application of excessive heat upon 
the switch when soldering can cause 
degradation of switch operation. 
Therefore, be sure to keep within the 
conditions given below.
1) Manual soldering: use soldering irons 
(max. 350°C, within 3 seconds) capable 
of temperature adjustment. This is to 
prevent deterioration due to soldering 
heat. Care should be taken not to apply 
force to the terminals during soldering.
2) Automatic soldering: Soldering must 
be done as below;
260°C: within 6 seconds
350°C: within 3 seconds
2. Mounting
Please avoid use in which load would be 
applied to the sides (hatch part (both 
sides) shown below) of the switch in the 
direction indicated by the arrows. This 
could cause erroneous operation. Also, 
when using a metal installation board, 
please make allowance for burr direction 
designation and burr suppressing, etc., 
so that the burr side will not be on the 
switch installation side.
1) To secure the switch, please use an 
M3 small screw on a flat surface and 
tighten using a maximum torque of 0.29 
N·m. It is recommended that spring 
washers be used with the screws and 
adhesive be applied to lock the screws to 
prevent loosening of the screws. Please 
make sure not to apply adhesive onto the 
moving parts.
2) Be sure to maintain adequate 
insulating clearance between each 
terminal and ground.
3) Although it is possible to directly 
operate the pin plunger type from the 
lateral direction, please consult us if 
doing so.
4) After mounting please make sure no 
tensile load will be applied to the switch 
terminals.
5) Range of possible use: Please set the 
operation position to within the ranges in 
the following table so that there is 
sufficient insulation distance and to 
maintain contact reliability.
mm
6) PC board terminal type should be 
used if the products are to be soldered on 
the PC board. Solder terminal type is not 
for soldering on PC board.
3. Cautions regarding the circuit
1) In order to prevent malfunction in set 
devices caused by bounce and chattering 
during the ON-OFF switch operation, 
please verify the validity of the circuit 
under actual operating conditions and 
temperature range.
2) When switching inductive loads 
(relays, solenoids, buzzers, etc.), an arc 
absorbing circuit is recommended to 
protect the contacts.
4. Please verify under actual 
conditions.
Please be sure to conduct quality 
verification under actual operating 
conditions in order to increase reliability 
during actual use.
5. Switch selection
Please make your selection so that there 
will be no problems even if the operating 
characteristics vary up to ±20% from the 
standard values.
Actuator
Plunger/lever free
From mounting 
boss and hole 
center line
From standoff
Pin 
plunger
>9.2
>13.4
Leaf lever
>10.7
>14.9
Simulated 
leaf lever
>13.5
>17.7
Actuator
Plunger/Lever pushed
From mounting 
boss and hole 
center line
From standoff
Pin 
plunger
7.8 to 5.9
12.0 to 10.1
Leaf lever
8.4 to 6.2
12.6 to 10.4
Simulated 
leaf lever
11.1 to 8.7
15.3 to 12.9
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.