Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC Fan
Built-in fan speed control
Fixed switching frequency at 100KHz
3 years warranty
SPECIFICATION
SP-320-5
SP-320-3.3
SP-320-7.5 SP-320-12 SP-320-13.5 SP-320-15 SP-320-24 SP-320-27 SP-320-36 SP-320-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
Note.2
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
5V
3.3V
7.5V
12V
13.5V
15V
24V
27V
36V
48V
55A
55A
40A
25A
22A
20A
13A
11.7A
8.8A
6.7A
0 ~ 55A
0 ~ 60A
0 ~ 40A
0 ~ 25A
0 ~ 22A
0 ~ 20A
0 ~ 13A
0 ~ 11.7A
0 ~ 8.8A
0 ~ 6.7A
275W
181.5W
300W
300W
297W
300W
312W
315.9W
316.8W
321.6W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
220mVp-p
240mVp-p
4.5 ~ 5.5V
3.14 ~ 3.63V
6 ~ 9V
10 ~ 13.2V 12 ~ 15V
13.5 ~ 18V 20 ~ 26.4V 26 ~ 31.5V 32.4 ~ 39.6V 41 ~ 56V
±2.0%
±1.0%
±2.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
±0.2%
±1.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
800ms, 50ms/230VAC          2500ms, 50ms/115VAC at full load
16ms/230VAC          16ms/115VAC at full load
88 ~ 264VAC          124 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC          PF>0.98/115VAC at full load
79%
5A
2.5A
74%
2.5A
1.5A
83%
9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V
27.6 ~ 32.4V 33.7 ~ 39.2V
57.6 ~ 67.2V
45 ~ 52.5V
86%
86%
86%
87%
88%
89%
87%
20A/115VAC          40A/230VAC
<1mA / 240VAC
105 ~ 135% rated output power
5.75 ~ 6.75V
3.8 ~ 4.5V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL60950-1, TUV EN60950-1, CCC GB4943(except for 3.3V, 36V) approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
-20 ~ +65
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
±
℃)
0.03%/
(0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
207K hrs min.      MIL-HDBK-217F (25
)
215*115*50mm (L*W*H)
1.1Kg; 12pcs/14Kg/0.92CUFT
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
SP-320
series
320W Single Output with PFC Function
115VAC
230VAC
AC CURRENT
(Typ.)
(except for 3.3V, 36V)
EMC IMMUNITY
EMC EMISSION
File Name:SP-320-SPEC   2013-12-17