Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Enter/Exit Programming Mode
150
PowerScan™ PD9530/PBT9500/PM9500
Code 11 Set Length 2
This feature specifies one of the bar code lengths for 
. Length 2 is the maximum label length if in 
 Mode, or the 
second fixed length if in 
 Mode. Length includes the bar code’s 
check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to 
ignore this length (only one fixed length).
 provides examples for setting Length 2. See 
 for detailed 
instructions on setting this feature.
Table 17. Code 11 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting (pad with 
leading zeroes)
00 (Ignore This 
Length)
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 11 LENGTH 2 SETTING
4
Scan Two Characters From 
 ‘0’ and ‘0’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ and 0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CC1.2
Select Code 11 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters