Enter/Exit Programming Mode
2D Global Features
184
PowerScan™ PD9530/PBT9500/PM9500
Data Matrix Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for this symbology.
Variable Length: 
For variable length decoding, a minimum and maximum 
length may be set.
Fixed Length: 
For fixed length decoding, two different lengths may be set.
DEFAULT
$CDMLC00(CR)
Data Matrix Length Control = Variable Length
$CDMLC01(CR)
Data Matrix Length Control = Fixed Length
Data Matrix Set Length 1
Specifies one of the bar code lengths for 
. Length 
1 is the minimum label length if in 
Variable Length
 Mode, or the first fixed 
length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 
characters in increments of 0001 (pad with zeroes).
See 
 for detailed instructions on setting this feature.
$CDML1
Select Data Matrix Length 1 Setting
To configure this feature, scan the ENTER/EXIT 
PROGRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in 
 repre-
senting your desired character(s). End by scanning 
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
~
CANCEL
DEFAULT
0001 = Length 1 is 1 Character