Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
2D Global Features
Enter/Exit Programming Mode
Product Reference Guide
                           193
Micro PDF417 Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for this symbology.
Variable Length: 
For variable length decoding, a minimum and maximum 
length may be set.
Fixed Length: 
For fixed length decoding, two different lengths may be set.
DEFAULT
$CMILC00(CR)
Micro PDF417 Length Control = Variable Length
$CMILC01(CR)
Micro PDF417 Length Control = Fixed Length
Micro PDF417 Set Length 1
Specifies one of the bar code lengths for 
Length 1 is the minimum label length if in 
Variable Length
 Mode, or the first 
fixed length if in Fixed Length Mode. Length includes the bar code’s data 
characters only. Characters can be set from 0001 to 0366 characters (pad 
with zeroes) in increments of 01. Any value greater than 0366 will be con-
sidered to be 0366.
See 
 for detailed instructions on setting this feature.
$CMIL1
Select Micro PDF417 Length 1 Setting
To configure this feature, scan the ENTER/EXIT 
PROGRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in 
 repre-
senting your desired character(s). End by scanning 
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
~
CANCEL
DEFAULT
0001 = Length 1 is 1 Character