Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Enter/Exit Programming Mode
212
PowerScan™ PD9530/PBT9500/PM9500
Beep Volume
Selects the beeper volume (loudness) of radio-specific beep indications. 
There are three selectable volume levels.
$CBTBV00(CR)
Beep Volume = Low
$CBTBV01(CR)
Beep Volume = Medium
$CBTBV02(CR)
Beep Volume = High
DEFAULT
Disconnect Beep 
Enables/disables the beep indication that a handheld has become connected 
or disconnected from a Base Station.
$CBTDB00(CR)
Disconnect Beep = Disable 
$CBTDB01(CR)
Disconnect Beep = Enable
DEFAULT
The defaults are different for the STAR and Bluetooth models.