Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Enter/Exit Programming Mode
Product Reference Guide
                           217
Erase Batch Memory
When the scanner is configured in Manual Batch Mode, use the following bar 
code to erase any labels stored in batch memory.
BatchClear
Erase Batch Memory
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunc-
tion with this bar code.
RF Batch Mode Transmit Delay
Specifies the delay in 10 msec increments between transmitting labels 
stored in batch memory.
DEFAULT
$CBTTD00(CR)
RF Batch Mode Transmit Delay = No Delay
$CBTTD05(CR)
RF Batch Mode Transmit Delay = 50 mS
$CBTTD0A(CR)
RF Batch Mode Transmit Delay = 100 mS
$CBTTD32(CR)
RF Batch Mode Transmit Delay = 0.5 seconds
$CBTTD64(CR)
RF Batch Mode Transmit Delay = 1 second
$CBTTDFA(CR)
RF Batch Mode Transmit Delay = 2.5 seconds