Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Enter/Exit Programming Mode
248
PowerScan™ PD9530/PBT9500/PM9500
Display Off Timeout
Sets the timeout for display, backlight and keyboard. 
Display Off Timeout = Disabled
$CDIOT
Set Display Off Timeout
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at 
left followed by two digits from the Alphanumeric 
characters in 
 representing 
your desired character(s). End by scanning the ENTER/
EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start again 
at the beginning.
~
CANCEL
DEFAULT
08 = 8 second delay
Backlight Enable 
Enables/Disables the display backlight.
DEFAULT
$CDIBL00\r
Backlight Disabled
$CDIBL01\r
Backlight Enabled