Enter/Exit Programming Mode
Product Reference Guide
                           253
CONFIGURE ACTIONS FOR FUNCTION KEYS
Each of the function keys can be programmed to perform a user-assigned 
function. This is done by associating a function key with either a predefined 
command or your own custom string. See the "
command to define customized strings. 
Each function key has an associated label which shows in the display when 
active. The default labels are shown in the table below. To program the 
function key labels, see "
The following table shows the list of predefined commands and available 
strings.
Table 27. Keyboard Programming 
CMD_ID
Name
Function
Default 
Label
16K
4K
0
Not configured
 
Not configured action.
 
 
If a key must be kept enabled but isn’t required 
in normal mode , this function can be selected to 
keep it ineffective. Whenever an unconfigured 
function key is pressed, an error message 
appears on the display and an error beep is 
emitted. 
<None>
1
Enter CMD
Same as ENTER_KEY.  
Ent
2
String 1
Display and transmit string 1.
S1T
3
String 2
Display and transmit string 2.
S2T
4
String 3
Display and transmit string 3.
S3T
5
String 4
Display and transmit string 4.
S4T
6
String 5
Display and transmit string 5.
S5T
7
Backlight CMD
Toggle backlight on/off.
Blt
8
Clear CMD
Clears the screen
CLR
9
Backspace CMD
Same as Backspace key. 
A
Recall
If pressed once, it recalls the last code sent out.
 
If pressed twice, resends the last code. 
Rcl
B
Show Date/Time Display the internal date, time.
Tim
C
Scroll Up
Scroll up between multiple function
˅
D
Scroll Down
Scroll down between multiple function
˄
E
Dot char
Display dot [.] char
[.]
F
Dynamic 
 
Quantity
Dynamic Quantity Code function
Qty