Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
References
282
PowerScan™ PD9530/PBT9500/PM9500
Intercode Delay
Specifies the delay between labels transmitted to the host for this interface. 
The selectable range for this feature is from 0 to 99 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 0 
= 00, 5 = 05, 20 = 20, etc
3. Go to 
 and scan the ENTER/EXIT PROGRAMMING MODE bar code 
to enter Programming Mode.
4. Scan the bar code: SELECT INTERCODE DELAY SETTING.
5. Scan the appropriate two digits from the keypad in 
, that represent the duration which was determined in the steps 
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar 
code to abort and not save the entry string. You can then start again 
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See 
 for some examples of how to 
set this feature.
Table 37. Wedge Intercode Delay Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
No Delay
5 Seconds
60 Seconds
99 Seconds
2
Pad with leading zero(es)
00
05
60
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT INTERCODE DELAY SETTING
5
Scan Two Characters From 
 ‘0’ and ‘0’
 ‘0’ and ‘5’
‘6’ and ‘0’
‘9’ AND ‘9’
6