Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Technical Specifications
320
PowerScan™ PD9530/PBT9500/PM9500
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has 
not passed its automatic Selftest and has entered FRU (Field Replaceable 
Unit) isolation mode. If the reader is reset, the sequence will be repeated. 
Press and release the trigger to hear the FRU indication code.
The following table describes the LED flashes/beep codes associated with an 
error found.
NUMBER OF 
LED FLASHES/
BEEPS
Error
CORRECTIVE ACTION
1
Configuration
Contact Helpdesk for 
assistance
2
Interface PCB
6
Digital PCB
11
Imager
Base Station Indications (Cordless Models ONLY)
Base Station Button Indicators
BUTTON PUSH 
EVENT
CORDLESS
RED 
INDICATOR(**)
GREEN 
INDICATOR(**)
Push at power-up
force device connection 
(Aladdin)
Off
Slow blink
 
Fast blink
< 5 sec 
Paging 
Off
Fast blink
5 to 10 sec 
Unlink (Only Bluetooth)
Off
Slow blink
Programming Mode Indications (continued)
INDICATION
DESCRIPTION
LED
BEEPER
Label Program-
ming Mode Accep-
tance of 
Programming
Configuration option(s) 
have been successfully 
programmed via labels 
and the reader has exited 
Programming Mode.
N/A
Reader sounds one 
high frequency 
beep and 4 low fre-
quency beeps fol-
lowed by reset 
beeps.
Label Program-
ming Mode Cancel 
Item Entry
Cancel label has been 
scanned.
N/A
Reader sounds two 
times at low fre-
quency and current 
volume.