Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Enter/Exit Programming Mode
34
PowerScan™ PD9530/PBT9500/PM9500
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK charac-
ter from the host following label transmission. The selectable timeout range 
is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A 
selection of 0 disables the timeout. 
See 
 for more information on setting this feature.
$CR2AT
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT 
PROGRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in 
 repre-
senting your desired character(s). End by scanning 
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
~
CANCEL
DEFAULT
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label trans-
mission due to a retry condition. The selectable range is from 1 to 254 
retries. A selection of 0 disables the count, and a selection of 255 specifies 
unlimited retries. Se
 for more information.
$CR2AR
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT 
PROGRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in 
 repre-
senting your desired character(s). End by scanning 
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
~
CANCEL
DEFAULT
003 = 3 Retries