Arnold Rak 2.5 m Heating Cable / HK-2,5 数据表
![Arnold Rak](https://files.manualsbrain.com/attachments/059232e3105f94068fa6b7cfbdbf8fb70d495ae9/common/fit/150/50/536c5eece80aeff15b3d8ace265b7ffe90a7c67f2851983456d1799304c2/brand_logo.gif)
产品代码
HK-2,5
Installation
Instructions
Heating Cables
Product information
The heating cables are resistance heating cables to DIN VDE 0253 and are supplied ready for connection.
They are suitable for a wide range of applications, including heating terrariums, cold frames, greenhouses,
young animal breeding stations or foundations of cold-storage warehouses.
The heating cable with frost protection function is specially designed as a pipeline heating system and is
automatically turned on at a temperature of less than 5° C.
The heating cable with a voltage of 12 V is designed as a flexible, open-ended connection cable and is
suitable for use in e.g. vehicles, caravan or boat building or specifically for greenhouses with a 12 V solar
system.
They are suitable for a wide range of applications, including heating terrariums, cold frames, greenhouses,
young animal breeding stations or foundations of cold-storage warehouses.
The heating cable with frost protection function is specially designed as a pipeline heating system and is
automatically turned on at a temperature of less than 5° C.
The heating cable with a voltage of 12 V is designed as a flexible, open-ended connection cable and is
suitable for use in e.g. vehicles, caravan or boat building or specifically for greenhouses with a 12 V solar
system.
Type
Rated
voltage
Power
per m
Total
power
Length
Frost
protection
function
Connection
Minimum
bending
radius
Max.
surface
temperature
HK-2,5-F
230 V
15 W
37 W
2.5 m
yes
Safety contact
plug, VDE
1.5 cm
105° C
HK-5,0-F
230 V
15 W
75 W
5.0 m
yes
Safety contact
plug, VDE
1.5 cm
105° C
HK-8,0-F
230 V
15 W
120 W
8.0 m
yes
Safety contact
plug, VDE
1.5 cm
105° C
HK-12,0-F
230 V
15 W
180 W
12.0 m
yes
Safety contact
plug, VDE
1.5 cm
105° C
HK-2,5
230 V
15 W
37 W
2.5 m
no
Safety contact
plug, VDE
1.5 cm
105° C
HK-5,0
230 V
15 W
75 W
5.0 m
no
Safety contact
plug, VDE
1.5 cm
105° C
HK-8,0
230 V
15 W
120 W
8.0 m
no
Safety contact
plug, VDE
1.5 cm
105° C
HK-12,0
230 V
15 W
180 W
12.0 m
no
Safety contact
plug, VDE
1.5 cm
105° C
HK-5,0-12
12 V
15 W
75 W
5.0 m
no
without plug
1.5 cm
105° C
HK-8,0-12
12 V
15 W
120 W
8.0 m
no
without plug
1.5 cm
105° C
HK-12,0-12
12 V
15 W
180 W
12.0 m
no
without plug
1.5 cm
105° C
GB