Arnold Rak 100 m Heating Cable / 16-100-F 数据表

产品代码
16-100-F
下载
页码 2
 
   
 
 
 
Application Examples 
 
 
Application: Pipe heating   
 
(type HK-xxx-F) 
 
Pipe heating systems can be installed on practically any pipe in order to protect them against frost or 
to maintain  the  required  temperature of  hot  water  pipes (e.g.  provision  of  drinking  water for  animals 
outdoors and in stables). 
 
The  completely  pre-assembled  and  directly  applicable  heating  cable  contains  a  thermostat  which 
ensures the energy-saving control of the heating cable. The thermostat automatically turns on (at app. 
+5º C) so that freeze-up can be excluded.
 
 
Installation notes: 
First, place the thermostat with the flat side at the coldest point on the bottom of the pipe and attach it 
with  self-adhesive  aluminium  foil  making  sure  that  it  has  the  largest  possible  contact  area  with  the 
pipe. 
Depending  on  the  required  heating  performance,  the  heating  cable  is  installed  below  the  pipe. 
Alternatively, the heating cable can be wound around the pipe (minimum distance between loops 10 
cm). Make sure that the entire heating cable is attached to the pipe. Shortening the heating cable is 
not permitted.
 
The heating cable is glued to the pipe with self-adhesive aluminium foil at regular intervals to ensure a 
continuous contact of heating cable and pipe and to eliminate the possibility of the heating cable being 
pushed into the pipe insulation material. 
 
For plastic pipes, the pipe should subsequently be wrapped with self-adhesive aluminium foil in order 
to achieve a better heat transfer. 
 
Before attaching the pipe insulation material, a visual inspection for damages should be conducted. 
The  pipe  insulation  must  then  be  fixed  with  commercially  available  insulation  material  (min.  R-value 
0.035  W/mK).  This  is  absolutely  necessary  in  order  to  achieve  the  required  frost  protection  and 
reduces power consumption.
 
Finally, the heating cable must be connected to a power outlet (230 V) protected with max. 6 A. 
 
Identification  labels  should  be  attached  to  the  pipe  insulation  material  at  regular  intervals  (4  m) 
indicating that the pipe is heated.  Operation of the heating cable in conjunction with a residual current 
circuit breaker is recommended.
 
 
 
Application: Seeding and nursing of plants 
 
Electric heating cables provide an effective germination aid and accelerate growth by heating the soil, 
especially in cold frames. 
The heating cable is laid out on the ground in meanders according to the given conditions. Spacers 
can be used to maintain the desired distances. Installation in a screed layer is sensible.
 
The embedding depth of the heating cable primarily depends on the plant structure. The plants’ roots 
should not come into contact with the heating cable.
 
To  prevent  damage  to  the  heating  cable  by  gardening  tools,  a  steel  reinforcing  matt  can  be  placed 
over the heating cable. Additionally, a notice warning that the beds are heated can be attached.