Secuself Wireless door alarm EL-2601 / E8US007MAG0A EL-2601 / E8US007MAG0A 数据表
产品代码
EL-2601 / E8US007MAG0A
EL-2601 Wireless magnetic contact – Funkmagnetkontakt – Contact magnétique –
Magneet contact Conrad No: 1276474
enters Test mode during which a transmission is sent every few seconds. You
can terminate Test mode by closing the Tamper switch.
Note: Due to the occurrence of voltage delay in lithium batteries that
have been in storage, the batteries may initially appear to be dead. In
this case, leave the unit in Test mode for a few minutes until the battery
voltage level is stabilized.
When handling the PCB, do not apply pressure on the antenna.
3. From the Programming menu, select Devices, Zones [911].
4. Select the zone to which you want to register the transmitter; the system
initiates Registration mode.When Save? appears on the panel’s LCD display,
press „Yes“.
5. After registration, press the EL-2601
can terminate Test mode by closing the Tamper switch.
Note: Due to the occurrence of voltage delay in lithium batteries that
have been in storage, the batteries may initially appear to be dead. In
this case, leave the unit in Test mode for a few minutes until the battery
voltage level is stabilized.
When handling the PCB, do not apply pressure on the antenna.
3. From the Programming menu, select Devices, Zones [911].
4. Select the zone to which you want to register the transmitter; the system
initiates Registration mode.When Save? appears on the panel’s LCD display,
press „Yes“.
5. After registration, press the EL-2601
’s tamper switch to terminate Test mode.
6. Before permanently mounting the unit, test the transmitter from the
exact mounting position.
7. To remove the PCB, press the PCB release tab and carefully lift the board and slide the board away from the back cover.
8. The EL-2601 is able to operate in three modes: Magnetic Switch, Universal Transmitter or a combination of the two. If
connecting a wired contact loop (N.C.), connect the terminal block as follows: 1 - Alarm; 2 - GND. For this purpose, a wiring
knockout is provided in the back cover.
9. Mount the back cover using two screws and replace the PCB. Use ISO 7050 (ST3.5 x 22) or similar countersunk
screws so that the screw head will not touch the PCB
exact mounting position.
7. To remove the PCB, press the PCB release tab and carefully lift the board and slide the board away from the back cover.
8. The EL-2601 is able to operate in three modes: Magnetic Switch, Universal Transmitter or a combination of the two. If
connecting a wired contact loop (N.C.), connect the terminal block as follows: 1 - Alarm; 2 - GND. For this purpose, a wiring
knockout is provided in the back cover.
9. Mount the back cover using two screws and replace the PCB. Use ISO 7050 (ST3.5 x 22) or similar countersunk
screws so that the screw head will not touch the PCB
– see Figure B.4.
10. To open the ma
gnet’s housing, insert a small screwdriver into one of the pryoff slots located at either end of the magnet’s
back cover and lift to separate from the front cover.
11. Mount the back cover of the magnet using two screws. Make sure that the
guideline on the magnet is correctly aligned with the guideline on the transmitter. Do not install the magnet further than 1cm from
the transmitter.
12. Test the transmitter, making certain that the LED is lit when opening the door/window and again when closing.
13. Close the front covers of the transmitter and the magnet.
11. Mount the back cover of the magnet using two screws. Make sure that the
guideline on the magnet is correctly aligned with the guideline on the transmitter. Do not install the magnet further than 1cm from
the transmitter.
12. Test the transmitter, making certain that the LED is lit when opening the door/window and again when closing.
13. Close the front covers of the transmitter and the magnet.
TECHNICAL DATA
Antenna: Built-in Whip
Frequency: 868.35MHz FM
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 25mA (transmission)
10
Antenna: Built-in Whip
Frequency: 868.35MHz FM
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 25mA (transmission)
10
μA (standby)
Loop Input Voltage Range: 0-15VDC/AC (peak to peak)
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 65 x 30 x 25mm
RFI Immunity: 40V/m
Operating Temperature: 0 to 60°C
Dimensions: 65 x 30 x 25mm
France
CONTACT MAGNÉTIQUE
Le EL 2601 est un contact magnétique conçu pour une installation sur des portes
et des fenêtres. Ce produit fait partie de la série Electronics Line Secuplace et
fonctionne avec le système d’alarme Secuplace. Pour en
savoir davantage sur le système complet, les possibilités et le
réglage de la série Secuplace,voyez les instructions d’installation
sur notre site
CONTACT MAGNÉTIQUE
Le EL 2601 est un contact magnétique conçu pour une installation sur des portes
et des fenêtres. Ce produit fait partie de la série Electronics Line Secuplace et
fonctionne avec le système d’alarme Secuplace. Pour en
savoir davantage sur le système complet, les possibilités et le
réglage de la série Secuplace,voyez les instructions d’installation
sur notre site