Gnb Sonnenschein A412/50 A, 12V Ah lead acid battery NGA4120050HS0CA NGA4120050HS0CA 数据表
产品代码
NGA4120050HS0CA
Edition: Sept. 2014
The Master document is located electronically. Printed copies of this document are not controlled, unless identified as such. The USER has to assure the document is valid prior to use.
8. Exposure limits and personal protective equipment
8.1 Lead and Lead compounds
No exposure to lead and lead-containing battery paste during normal conditions of use.
8.2 Electrolyte (Sulphuric Acid)
Exposure to sulphuric acid and acid mist might occur during filling and charging. Occupational
exposure limits for sulphuric acid mist are regulated national basis.
exposure limits for sulphuric acid mist are regulated national basis.
Hazard Class: Skin corrosive 1A
Protective equipment: P280 Wear protective gloves/protective clothing and eye/face protection.
CAS-No: 7664-93-9
Hazard Statement: H314 Cause severe skin burns and eye damage
Precautionary Statements: P102 Store away and keep out of reach of children
P210 Keep away from heat/sparks/open flames. – No
smoking
P303+P361+P353 If on Skin or Clothing, remove immediately all clothing,
rinse skin with water, take a shower and seek medical
advice
P305+P351+P338 If in contact with eyes rinse immediately with plenty of
water, remove contact lenses and seek medical advice
P309 If exposed or if you feel unwell seek medical advice
immediately (show the label where possible).
smoking
P303+P361+P353 If on Skin or Clothing, remove immediately all clothing,
rinse skin with water, take a shower and seek medical
advice
P305+P351+P338 If in contact with eyes rinse immediately with plenty of
water, remove contact lenses and seek medical advice
P309 If exposed or if you feel unwell seek medical advice
immediately (show the label where possible).
9. Physical and Chemical properties
Lead and Lead compounds
Electrolyte
(diluted sulphuric acid, 30 to
38.5%)
Appearance
form :
colour :
odour :
solid
grey
odourless
liquid
colourless
odourless
Safety-related data
solidification point :
boiling point :
solubility in water :
density (20°C) :
vapour pressure (20°C) :
327 °C
1740 °C
very low (0.15 mg/l)
11.35 g/cm³
N.A.
-35 to -60 °C
approx. 108 to 114 °C
complete
1.2 to 1.3 g/cm³
14,6 mbar
Lead and Lead compounds used in Lead-Acid batteries are poorly soluble in water, Lead can be