Features
  Large package size
  For use with precision potentiometers up to 
 20 
turns
 Excellent readability
  Precision feel - no backlash
 Cast housing
 RoHS compliant*
Applications
 Power supplies
 Sensors
 Medical
 Automation
 Test equipment
 
  H-46  Turns-Counting Dial
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex. 
 Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
REV. 03/09
*RoHS COMPLIANT
  Mechanical and Physical Characteristics
Number of Turns ............................................................................................................................................................................. 0 to 20
Dial Divisions ...........................................................................................................................................................................100 per turn
Readability – Over 10 Turns .....................................................................................................................................Within 1/100 of a turn
Torque With Brake Engaged ..............................................................................................................21.18 N-cm (30.0 oz.-in.) maximum
Markings ..................................................................................................................................................... Black on chrome background
Locking Brake .......................................................................................................................................................................................Yes
Weight ............................................................................................................................................................................73 grams (2.5 oz.)
Set Screw .......................................................................................................................................................... UNC N4-44, one included
Set Screw Tightening Torque ...............................................................................................................16.94 N-cm (1.5 lbs.-in.) minimum
Hex Key Size ............................................................................................................................................................................0.05 in. hex
  Shaft and Bushing Requirements
Shaft Diameter Requirements ................................................................................................................................... Refer to chart below
Shaft Extension Beyond Panel ................................................................................................................... 17.5 mm (0.689 in.) minimum
   
23.5 mm (0.925 in.) maximum
Bushing Extension Beyond Panel ................................................................................................................ 4.5 mm (0.177 in.) maximum
 
H-46 MOUNTING INSTRUCTIONS
 
Using the existing Antirotation Lug
 
1. Drill 3.2 mm (0.125) diameter antirotation
 
   pin hole on vertical centerline 14.3 mm 
 
  (0.562) below center of potentiometer 
  
mounting 
hole.
 
2. Mount potentiometer shaft counterclock-
 
  wise to obtain minimum resistance or 
 
  voltage ratio. This is not necessarily 
 
  identical with the mechanical stop.
3.  Loosen set screws in knob of dial. Set dial to “0.0” reading.
4.  While holding outer ring of dial, position unit lightly against 
 
panel. Tighten knob set screws to potentiometer shaft.
How To Order
 
Part Accepts 
Shaft 
 Number  Diameter 
Finish
 
H-46-6A 
  6.35 mm (.250)
 Satin 
    
Chrome
 
H-46-6M    6 mm (.236)
 Satin 
    
Chrome
 
 
 
Using the Antirotation Device
 
 
1.  Remove antirotation lug from dial 
 
 
 
by using pliers.
 
 
2.  Mount potentiometer in panel with 
 
 
 
antirotation device nut (supplied 
 
 
 
with dial) and lockwasher (supplied
  
 
with 
potentiometer).
 
 
3.  Turn potentiometer shaft counter-
 
 
 
clockwise to obtain minimum 
 
 
 
resistance or voltage ratio. This is 
 
 
 
not necessarily identical with the
  
 
mechanical 
stop.
4.  Loosen set screws in knob of dial. Set dial to “0.0” reading.
5.  While holding outer ring of dial, position unit lightly against panel. 
 
Tighten knob set screws to potentiometer shaft. 
Dimensional Drawings
DIMENSIONS:
 MM
 (INCHES)
24.0
(.944)
12.50
(.492)
46.0
(1.811)
10.31
(.405)
14.30
(.562)
3.17
(.124)
PANEL LAYOUT
DIA.
DIA.