MULTIPLEX COCKPIT SX M-LINK "telemetry"-Set 25131 数据表

产品代码
25131
下载
页码 72
C
OCKPIT
 SX M-LINK 
MULTIPLEX Modellsport GmbH & Co.KG  •  Westliche Gewerbestraße 1  •  D-75015 Bretten (Gölshausen)  •  www.multiplex-rc.de          Page 26 
12.5. 
Link Quality Indication (LQI) 
12.5.1.  Display of LQI value on the transmitter’s  
 integral 
screen 
In addition to the receiver battery voltage, telemetry-
capable M-LINK receivers generate a value for recep-
tion quality (LQI = Link Quality Indication). No external 
sensors need to be connected to the telemetry-capable 
receiver in order to send these two values to the trans-
mitter. 
The factory default setting for the LQI value display on 
the C
OCKPIT
 SX M-LINK is INFO display 8, i.e. address 
1
(
Π12.2.2.). 
12.5.2.  Definition of terms 
a) “Transmitter” and “receiver” 
Although the terms “transmitter” and “receiver” are no 
longer technically precise (after all, telemetry-capable 
transmitters and telemetry-capable receivers both 
transmit and receive), this supplement continues to use 
these two terms in their usual sense. 
b) Uplink and downlink 
Uplink, or “out” channel: 
ΠConnection from transmitter to receiver. 
Downlink or “back” channel: 
ΠConnection from receiver to transmitter. 
12.5.3.  Indicated range of LQI values 
The range of LQI values displayed on the transmitter’s 
screen extends from
%
100  (best possible value) down 
to 
%
0 .
As the link quality declines - typically when the distance 
between the model and the transmitter is increasing, or 
when the model is in an unfavourable attitude - this 
value diminishes in increments of 10%. 
The LQI value shows the quality of the data trans-
mission from transmitter to receiver, i.e. it provides a 
value for the quality of the uplink. The value is 
calculated from the signal field strength and other 
parameters. Since the field strength varies according to 
the model’s attitude, and the model’s position is subject 
to wide variations, the system automatically smoothes 
out the value, taking further parameters into con-
sideration. 
12.5.4.  Interpreting the LQI value 
a) General information 
The sensitivity of the field strength measurement is 
lower than the sensitivity of the M-LINK receiver itself. 
This means that the receiver can certainly continue to 
function even when the LQI value falls to 
%
0 .
The transmitting power of the transmitter and receiver 
is the same. Nevertheless the downlink channel - i.e. 
the connection from the receiver to the transmitter - 
breaks down earlier than the uplink channel. The 
reason for this is the low sensitivity of the transmitter; it 
is as if the transmitter were wearing “ear defenders”.
b) Normal operations 
During normal operations (flying a model) the downlink 
connection usually breaks down when the link quality 
falls to an LQI value of about 
%
60 . At this point the last 
telemetry value assessed as valid is retained per-
manently on the transmitter screen, i.e. the screen 
display “freezes”. 
All the telemetry values are updated when the trans-
mitter picks up new data. 
Note: 
If the downlink connection collapses at a value of 
about 
%
60 , for example, the connection with the 
model (i.e. the uplink) continues to function. 
c) Range check mode 
When you select “range check” mode, the transmitted 
power of the uplink channel is very greatly reduced 
compared with the downlink channel (
Π3.2.). For this 
reason the LQI display is an excellent means of 
establishing the ideal orientation of the receiver 
aerial(s) during the range check procedure: 
A good method of optimising the aerial position in or on 
the model is successively to alter the orientation of the 
receiver aerial(s) whilst carrying out repeated range 
checks, all the while observing the displayed LQI 
values. 
Note: 
The displayed LQI value may well show only 
%
10  or 
%
20  in range check mode, but the model will still be 
under full control.
13.  Setting up a new model 
Model type: 
EASY
13.7.4. Model 
type 
EASY: changing the standard
 
assignment for receiver output 
5 (aileron), 
 Menu: 
(
MIXER) AI->S5
If you have set up a new model using the 
EASY model 
type, then receiver output 
5 is assigned to the second 
aileron servo. If this is what you want, you do not need 
to make any changes in this menu. 
However, many model aircraft feature no ailerons at all, 
or only require a single servo to operate both ailerons. 
For such cases it is possible to assign receiver output 
5 to other functions, if you wish. 
You can control receiver output 
5 using any of the 
transmitter controls 
AI, EL, RU, TH, SP, F or the 
switch 
PH.
This change can be carried out in the menu point 
AI->S5 in the MIXER menu (see also Î
13.7.3.). 
How to access the menu 
AI->S5:
Action
Effect 
1. 
4
r
left to 
MENU
confirm 
SETUP appears 
2. 
3
r
right to 
MIXER
confirm 
TH->S4 appears 
3.  
3
r
right to  
AI->S5
confirm 
AI- flashes 
By turning the rotary control (
4 3) you can select the 
switch or transmitter control to which you want to as-
sign receiver output 5: