CHIPDRIVE 905464 数据表

下载
页码 59
CHIPDRIVE® Time Recording 
 
53 
 
Clock Communication Setup 
DHCP 
Enable/Disable 
Communication 
TCP/IP Server 
IP Address 
192.168.010.025 
Mask 
255.255.255.000 
Gateway 
000.000.000.000 
Server IP 
000.000.000.000 
Port 
5010 
 
DHCP: If your network uses a DHCP server, select Enable. Use the arrow keys to make your selection, 
and then select OK to confirm. Use the arrow keys to make your next selection. Press OK to confirm and 
exit the selection menu. 
For Communication, you can choose between TCP/IP Server and TCP/IP Client. CHIPDRIVE Time 
Recording only supports the default setting TCP/IP Server. The Server IP entry refers to the 
communication method "Client" and is therefore irrelevant. 
If you do not use a DHCP server, you need to enter a suitable IP Address and subnet mask (Mask). Open 
the respective selection menus with the OK key, highlight the number you want to modify using the 
arrow keys, and then override it by hitting a number key. Please note that all four numbers have to have 
three digits, e.g. "003." The Gateway and the Server IP entries are irrelevant for CHIPDRIVE Time 
Recording. The Port setting has to match the port setting configured for PC Time Clock Server (see 
chapter 3.4.4). 
If you select DHCP = Enable, the IP AddressMask and Gateway fields are locked because these 
parameters are retrieved automatically from the DHCP server. 
Note: Please note that an IP address automatically assigned by the DHCP server can change. Therefore it 
might make sense to use a manually assigned, static IP address. 
The changes for Comm. Setup do not take effect until the terminal is restarted. To enforce a restart, 
quickly cut the power supply. 
6.2.1.2 Device ID (= Terminal ID) 
Apart from the IP address and port settings, each fingerprint terminal requires a unique terminal ID. To 
set the terminal ID, select Clock Setup - Advanced Setup - Clock Options. Press the right arrow key twice 
to highlight the Device ID, then hit OK to enable the field. You can delete the default number by hitting 
the C key. Enter an up to 4-digit device number, and make sure that there are no similarities with 
terminal IDs of existing CHIPDRIVE® terminals (see chapter 3.4). 
Important: The device allows the entry of up to nine digits. But if you are using CHIPDRIVE® Time 
Recording, a maximum of four digits is supported. 
6.2.2  Computer Settings 
After configuring the IP address, port number, and device number, you can configure the connection 
between the terminal and the PC Time Clock Server installation. Follow the steps described in chapter 
3.4.4.