IBM Intel Xeon E7430 44E4470 数据表
产品代码
44E4470
Thermal Specifications
104
Intel® Xeon® Processor 7400 Series Datasheet
actions to protect the corresponding device and/or other system components from
overheating. The host controller may also implement an alert to software in the event
of a critical or continuous fault condition.
overheating. The host controller may also implement an alert to software in the event
of a critical or continuous fault condition.
6.3.2.4
PECI GetTemp0() and GetTemp1() Error Code Support
The error codes supported for the processor GetTemp0() and GetTemp1() commands
are listed in
are listed in
below:
§
Table 6-7.
GetTemp0() and GetTemp1() Error Codes
Error Code
Description
0x8000
General sensor error
0x8002
Sensor is operational, but has detected a temperature below its operational range
(underflow), currently 30
o
C absolute temperature.