12
P1522
FIG. 7 MAIN ON/OFF SWITCH TERMINALS
BLK from Fuse Holder
BLK to Solenoid (Water)
Switch #2 AFPO-2 & 3
MAIN ON/OFF SWITCH
FL
AV
OR
IN
PU
T
1
 
 
 
2
W
AT
ER
IN
PU
T
RE
FIL
L
MA
IN
PO
W
ER
2
1
1
2
3
3
3
FL
AV
OR
OU
TP
UT
FL
AV
OR
OU
TP
UT
W
AT
ER
OU
TP
UT
FL
AV
OR
OU
TP
UT
W
AT
ER
OU
TP
UT
W
AT
ER
OU
TP
UT
FIG. 6 MAIN ON/OFF SWITCH
P1516
Location:
The main ON/OFF switch is located on the lower
right  front  of  the  autofill  box  just  above  the  power
cord.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect  the black wire from the fuse holder
and the white wire from pump #1.
3. Connect the dispenser to the power source. Check
for voltage across the black wire removed from the
switch and the white wire removed from pump #1.
The indication must be:
a) 120 volts ac for 2 wire 120 volt models.
b) 200 to 240 volts ac for two wire 200 or 240 volt
models.
c) 230 volts ac for two wire 230 volt models.
4. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If  voltage  is  not  present  as  described,  refer  to  the
Wiring Diagrams and check the dispenser wiring har-
ness.
SERVICE (cont.)
28791 040501
5. Check for continuity across the switch terminals
with the switch in the “ON” position. Continuity
must  not  be  present  when  the  switch  is  in  the
“OFF” position.
If  continuity  is  present  as  described,  reconnect  the
wires to the switch terminals.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Remove the wires from the switch terminals.
2. Compress  the  clips  inside  the  autofill  box  and
gently push the switch through the opening
3. Push the new switch into the opening and spread
the clips to hold switch in the autofill box.