SECTION SIX: Interfacing the 957 system
Page 48
957 INSTALLATION MANUAL, Revision C1
0180, NMEA 0183, Datamarine CDX, or Raytheon 0183) to the 
RS-232 port’s output for direct connection to the computer.
1.
Press the STAR key to display the OPTIONS/SERVICE 
INFO screen, then press the PORT SETUP OPTIONS 
menu key.
2.
At the PORT SETUP OPTIONS screen, press the PORT 1 
SETUP
 or PORT 2 SETUP menu key to confirm that the 
port you want to copy is now set to output the desired 
data format. If necessary, make changes now by pressing 
the EDIT menu key, pressing ENTER when done, and the 
RETURN menu key to go back to the PORT SETUP 
OPTIONS screen.
3.
At the PORT SETUP OPTIONS screen, if necessary, change 
the RS-232 SETUP option to display the appropriate 
COPY PORT 1 or COPY PORT 2 selection by pressing the 
EDIT menu key, then pressing the CURSOR PAD to 
change the selection, then pressing the ENTER key. The 
unit will now copy and output the specified port’s data 
format through the RS-232 port to an external device.
Using the port off setting
Use this setting when you don’t need the RS-232 port’s input or 
output functions.
About the diagnostic
setting
This setting is only used for troubleshooting at the Northstar 
factory. Do not use this setting. 
NOTE:
The RS-232 diagnostic port may overflow—when
it’s configured to either 
COPY PORT1
 or 
COPY
PORT2
, and one of the copied ports is in 0183
output mode—unless the diagnostic port’s baud
rate is fast enough to handle the number of
characters. Because the diagnostic port’s baud rate
can now be changed, the 957 will always display
this precautionary message before you actually
reset the baud rate: 
WARNING: ALL
SENTENCES MAY NOT TRANSMIT AT DIAG
BAUD RATE. PRESS “ENTER” TO CONTINUE