Put power supply cord through the strain relief. Be sure 
that the wire insulation on the power supply cord is inside 
the strain relief. The strain relief should have a tight fit with 
the dryer cabinet and be in a horizontal position. Do not 
further tighten strain relief screws at this point.
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any 
screws from a 3/4" (19 mm) UL listed strain relief (UL 
marking on strain relief). Put the threaded section of the 
strain relief through the hole below the terminal block 
opening. Reaching inside the terminal block opening, 
screw the removable conduit connector onto the strain 
relief threads.  
A
B
C
A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads
Put direct wire cable through the strain relief. The strain 
relief should have a tight fit with the dryer cabinet and be 
in a horizontal position. Tighten strain relief screw against 
the direct wire cable.   
4. Now complete installation following instructions for your type 
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
If your home has:
And you will be 
connecting to:
Go to Section
4-wire receptacle
 
(NEMA Type 14-30R)
A UL listed, 
120/240-volt 
minimum, 
 
30-amp, dryer 
power supply 
cord*
4-wire connection:
Power supply cord
4-wire direct
(127 mm)
5"
A fused 
disconnect or 
circuit breaker 
box*
4-wire connection:
Direct Wire
3-wire receptacle
 
(NEMA type 10-30R)
A UL listed, 
120/240-volt 
minimum, 
 
30-amp, dryer 
power supply 
cord*
3-wire connection:
Power supply cord
3-wire direct
(89 mm)
3½"
A fused 
disconnect or 
circuit breaker 
box*
3-wire connection:
Direct Wire
Electrical Connection Options
*If local codes do not permit the connection of a cabinet-ground 
conductor to the neutral wire, go to “Optional 3-wire 
connection” section.
4-wire connection: Power Supply Cord 
IMPORTANT: A 4-wire connection is required for mobile homes 
and where local codes do not permit the use of 3-wire 
connections.
A
B
C
D
E
F
G
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL listed strain relief
G. Ring terminals
1. Remove center terminal block screw.