2
FIGURE 2 
- BENDIX
®
 TR-3
 INVERSION VALVE
FIGURE 3 
- BENDIX
®
 TR-3
 INVERSION 
VALVE INTERNAL BLEED CONTROL
The Bendix
® 
TR-3
 valve, with the internal control passage 
functions the same as described in the previous paragraph.  
The only exception is that the control pressure is always 
the same as the supply pressure. Consequently, as supply 
pressure builds up, when the pressure is great enough to 
overcome the piston return spring, the delivery pressure 
will  be  vented  out  the  exhaust.  On  descending  supply/
control  pressure,  as  the  piston  return  spring  overcomes 
the  control  pressure  the  valve  will  deliver  the  remaining 
supply pressure at the delivery port.
MOUNTING LOCATION
Care should be given to assure proper mounting location 
of the valve with the exhaust pointed downward (toward  
the road surface).  It should be mounted high on the frame 
rail,  and  away  from  road  spray  and  debris.  Unprotected 
or  exposed  exhaust  ports  can  allow  migration  of  road 
contaminants into the valve, which may cause accelerated 
wear or unintended operation.
PREVENTIVE MAINTENANCE
Important:  Review  the  Bendix  Warranty  Policy  before 
performing  any  intrusive  maintenance  procedures.  A 
warranty  may  be  voided  if  intrusive  maintenance  is 
performed during the warranty period.
No  two  vehicles  operate  under  identical  conditions,  as 
a  result,  maintenance  intervals  may  vary.  Experience  is 
a  valuable  guide  in  determining  the  best  maintenance 
interval for air brake system components. At a minimum, 
the  inversion  valves  should  be  inspected  every  six(6) 
months or 1500 operating hours, whichever comes fi rst, 
for  proper  operation.  Should  the  inversion  valves  not 
meet  the  elements  of  the  operational  tests  noted  in  this 
document,  further  investigation  and  service  of  the  valve 
may be required.
The TR-3 valve is non-serviceable while the Bendix
® 
TR-2
 
valve can be serviced with a maintenance kit.  For the latest 
service parts and kits, refer to the Bendix Quick Reference 
Catalog  (BW1114)  available  for  order  or  download  at 
www.bendix.com  
OPERATING AND LEAKAGE TESTS
NOTE:  The  following  checks  should  be  made  with  two 
calibrated  gauges  or  two  gauges  known  to  be 
accurate. Depending upon installation, it may be 
easier  or  necessary  to  completely  remove  the 
valve to test properly.
Install  one  test  gauge  in  a  common  control  and  supply 
line; install the other gauge in the delivery port. Gradually 
apply pressure to the common supply and control line. On 
ascending pressure, note at what pressure exhaust occurs 
and compare with the vehicle manual. With air pressure 
present in supply and control ports, apply a soap solution to 
the delivery and exhaust ports. Leakage should not exceed 
100 SCCM or a 1" bubble in 5 seconds. Excessive leakage 
would indicate a faulty o-ring or inlet valve. 
Slowly decrease pressure in the control cavity and note 
at what pressure delivery is made.  Compare this with the 
vehicle manual notation.
EXHAUST
DIAPHRAGM
1/4” P.T. 
DELIVERY
EXHAUST 
NUT
O-RING
O-RING
VALVE 
SPRING
O-RING
INLET &
EXHAUST
VALVE
PISTON
DIAPHRAGM 
RETAINER
CAP
1/8” P.T.
CONTROL
VALVE STOP
SHIM
PISTON SPRING
1/4” P.T. SUPPLY
INTERNAL 