National Instruments Power Supply PXI-1045 用户手册

下载
页码 7
NI PXI-1045 Power Supply Shuttle User Guide
6
ni.com
Maximum ripple and noise (20 MHz bandwidth)
Over-current protection ..........................All outputs protected from short 
circuit and overload with 
automatic recovery when the 
short or overload is removed.
Over-voltage protection
1
3.3 V ................................................140 to 150% above nominal 
output voltage
5 V, +12 V, –12 V ...........................120 to 130% above nominal 
output voltage
Power supply shuttle MTTR ...........Replacement in under 5 minutes
Voltage
Maximum Ripple and Noise
+3.3 V
50 mV
pp
+12 V
120 mV
pp
+5 V
 50 mV
pp
–12 V
 120 mV
pp
1   
To reset over-voltage protection, remove the MAINS for 30 seconds and then power up.