SERVICE
Location:
 
The fuse holder is located on the lower right front 
of the autofill box just to the left of the power cord.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Remove cap and fuse from fuse holder.
3.  Remove fuse from the cap.
4.  Check for continuity through the fuse.
If continuity is present, reinstall the fuse, the fuse is 
operating properly.
If continuity is not present, replace the fuse.
 
FIG. 4 FUSE HOLDER
P1516
FUSE AND FUSE HOLDER
Removal  and Replacement:
Fuse:
1.  Remove the cap from the fuse holder.
2.  Remove fuse from the fuse holder and inspect. If 
blown, discard.
3.  Install new 10 amp fuse in the fuse holder.
4.  Reinstall fuse holder cap.
Fuse Holder:
1.   Disconnect the dispenser from the power source.
2.  Disconnect  the  wires  from  the  rear  of  the  fuse 
holder.
3.  Remove  the  nut  securing  the  fuse  holder  to  the 
front of the main mounting panel.
4.  Push  the  fuse  holder  through  the  hole  in  the 
panel.
5.  Install new fuse holder and fuse through the hole 
in the panel.
6.  Secure the fuse holder to the panel. 
7.  Refer to Fig. 5 and reconnect the wires. 
BLK from Main
Wiring Harness
BLK to Main
ON/OFF Switch
FIG. 5 FUSE HOLDER TERMINALS
P1331