Horstmann C-Stat ZW 安装指南

下载
页码 16
3
Electrical Connections
WARNING:  ISOLATE  THE  MAINS  SUPPLY  BEFORE 
COMMENCING INSTALLATION
As the C-Stat is a wireless product with no electrical connections 
all electrical wiring will be made to the ASR-ZW receiver.
All necessary electrical connections should now be made. Flush 
wiring  can  enter  from  the  rear  through  the  aperture  in  the 
backplate.
The mains supply terminals are intended to be connected to the 
supply by means of fixed wiring.
The receiver is mains powered and requires a 3 Amp fused spur.
The recommended cable size is 1.0mm².
The receiver is double insulated and does not require an earth 
connection,  an  earth  connection  block  is  provided  on  the 
backplate  for  terminating  any  cable  earth  conductors.  Earth 
continuity  must  be  maintained  and  all  bare  earth  conductors 
must be sleeved. Ensure that no conductors are left protruding 
outside the central space enclosed by the backplate.
1
2
3
4
L
N
Internal
Electronics
230V
50Hz
COMM OFF
ON
ASR-ZW Receiver internal wiring diagram
The receiver has Voltage Free contacts. A link between Live and 
terminal 2 is required for mains Voltage applications.