Behringer B-Control Fader BCF2000-WH 用户手册

下载
页码 22
17
B-CONTROL  FADER  BCF2000/B-CONTROL  ROTARY  BCR2000
can also be set (release dynamic). Therefore, you can limit the
modulation range (FX depth) using After Touch.
MMC:
MIDI  Machine  Control  data  is  only  assignable  to  button
elements.
Encoder 4 (Value 1) sets “Locate Time” hour and minute values,
while encoder 5 (Value 2) sets seconds and frames. The Locate
Position is always sent before the MMC command. We therefore
have the following logic-switching sequence:
If the “Locate” parameter has been selected, the sequencer or
hard drive recorder always jumps to the set position. If “Play” has
been  selected  as  the  parameter  (for  a  button),  the  sequencer
always starts from the set locator point as soon as the button is
pressed.  “Rewind”  always  begins  at  the  chosen  locator  point.
Select the frame rate with encoder 6: 24, 25, 30 (non-drop), 30d
(drop frame) or “off” (in this case only the MMC message is sent,
without any information of the locate position).
GS/XG:
Encoder  3  directly  selects  the  most  important  “Main  Control”
parameters.  The  display  indicates  them  as  a  (shortened)  text
(table 4.2). In this case, these are CCs or NRPNs (no SysEx data).
Table 4.3: GS/XG Parameter Main Controls
Encoders  4  and  5  let  you  confine  or  invert  each  controllers’
value range.
4.5 Settings in the global setup menu
Settings that have an effect on all presets are made in the global
setup menu.
s
Keep the EDIT key pressed and at the same time press the
STORE key.
s
You are now in the global setup menu, and can let go of
both keys.
s
Now, turn the push encoders 1 to 8 to get the desired setting.
This is how the push encoders are allocated:
(QFRGHU
)XQFWLRQ
6HOHFW
1
Operating Mode
U-1 ... U-4, S-1 ... S-4
2
Global RX Channel
Off, 1 ... 16
3
Footswitch
Auto/Normal/Inverted
4
Start-Preset
1 ... 32, Last
5
Device ID
1 ... 16
6
SysEx Dump
Single/All
7
-
-
8
MIDI Data Interval
(ms)
Table 4.4: Push encoder allocation in global setup menu
s
To exit the global setup menu, press EXIT.
4. OPERATION
+
The  settings  in  the  global  setup  menu  take  effect
immediately and do not have to be separately stored.
Operating Mode:
The operating modes are described in chapter 4.1. You can
select USB modes U-1 to U-4 and stand-alone modes S-1 to S-4.
Global RX Channel:
The B-CONTROL receives program change commands on this
channel.
Footswitch type:
Because there are different kinds of footswitches (depending
on their switching behavior), the polarity of the footswitch connector
can be set (normal/inverted), or it can be automatically detected
during power startup (auto recognition).
Start Preset Number:
Each of the 32 presets can be selected as the startup preset.
Additionally, with the “Last” function, at startup you have the option
to always load the preset that was used last.
Device ID Number:
You  should  change  the  ID  number  settings  only  if  you  work
with  several  BCF2000s  or  BCR2000s  at  the  same  time,  and
problems with recognizing the correct device start occurring during
a SysEx Dump procedure.
+
Please  keep  in  mind  that  SysEx  Dumps  can  only  be
received at the device number to which they were sent!
SysEx Dump Select:
Turning  push  encoder  6  lets  you  select  between  the  current
preset (single) or the entire memory contents of the 32 presets
(all) should be sent as a SysEx dump. One press on encoder 6
triggers the dump.
To receive a SysEx dump, you don’t have to change any settings
on  your  equipment.  If  you  send  a  single  preset  to  the
B-CONTROL, the data is written to a temporary memory; to be
stored permanently, the data has to be stored on a storage slot of
your choice (preset store function).
+
WARNING:  If  you  send  an  “ALL-Dump”  to  the
B-CONTROL,  the  entire  memory  contents  are  directly
overwritten! No request to confirm will be made, and
the memory has no redundant safety function!
s
To cancel a SysEx dump, press the EXIT key.
MIDI Data Interval:
This is where you adjust the data transmission rate. This setting
only has an effect on MIDI data packs such as SysEx dumps and
not on controlling of MIDI commands (they are carried out in real
time anyway). The transmission rate is adjustable in milliseconds.
4.6 Additional functions
Temporary “Local Off”:
“Local Off” means that when you move a control element on
the B-CONTROL, no MIDI data is transmitted. If the position of a
control element deviates from the current value in the software,
you can readjust its position until the correct position is found by
using this function. After that, the control can be moved again
without creating an audible value deviation.
Deviations between the position of a control element  and the
current parameter value can occur if no parameter feedback is
being sent while a value is being changed in the software (e.g.
mixer automation).
s
Press the EXIT key and keep it pressed.
s
Move the desired control element until you get the correct
value.
s
Let go of the EXIT key. The control element can now be
moved again.