Behringer Europower PMP2000 用户手册

下载
页码 12
10
EUROPOWER PMP2000 User Manual
Monitor Output
Type 
¼" TRS connector, unbalanced
Impedance 
1.5 kΩ
Max. output level 
+21 dBu
DSP 
24-bit Texas Instruments
Converter 
24-bit Sigma-Delta, 
64/128-times oversampling
Sampling rate 
40 kHz
Main Mix System Data
1
Noise
Main mix @ -∞, 
-76 dB / -80 dB A-weighted 
Channel fader -∞
Main mix @ 0 dB, 
-72 dB / -76 dB A-weighted 
Channel fader -∞
Main Mix @ 0 dB, 
-71 dB / -75 dB A-weighted 
Channel fader @ 0 dB
Power Amp Specifi cations
RMS @ 1% THD (Sine Wave), Both Channels Driven:
8 Ω per channel 
165 W
4 Ω per channel 
250 W
RMS @ 1% THD (Sine Wave), Bridged Mode:
8 Ω 
500 W
Peak Power, Both Channels Driven
8 Ω per channel 
225 W
4 Ω per channel 
350 W
Peak Power, Bridged Mode
8 Ω 
800 W
Loudspeaker Connections
Loudspeaker connector 
Professional speaker con nectors 
(compatible to Neutrik Speakon)
Load Impedance
Left/monitor 
4/8/16 Ω
Right/mono main 
4/8/16 Ω
Bridge 
8/16 Ω
Power Supply
Voltage and Fuse
USA/Canada 
120 V~, 60 Hz 
T 10 A H 250 V
Europe/U.K./Australia 
230 V~, 50 Hz 
T 5 A H 250 V
China/Korea 
220 V~, 50/60 Hz 
T 6.3 A H 250 V
Japan 
100 V~, 50 – 60 Hz 
T 12 A H 250 V
General export model 
230 V~, 50 Hz 
T 5 A H 250 V 
120 V~, 60 Hz 
T 10 A H 250 V
Power consumption 
max. 1 kW
Mains connection 
Standard IEC receptacle
Dimensions/Weight
Dimensions (H x W x D) 
approx. 11 x 18 ⁄ x 10 ⁄" 
approx. 280 x 460 x 270 mm
Weight (net) 
approx. 30.9 lbs / 14 kg
Measuring conditions: 
1:  20 Hz - 20kHz; measured at preamp output. All channels: level controls in center position; EQ flat. 
Reference = 0 dBu.
BEHRINGER is constantly striving to manintain the highest professional standards. As a result of these eff orts, 
modifi cations may be made from time to time to existing products without prior notice. Specifications and 
appearance may differ from those listed or illustrated.