Oakleaf Woodburning stove
A. design, Installation & Location
Considerations
3
Getting started
1. Appliance Location
Consideration must be given to safety, convenience,
Consideration must be given to safety, convenience,
traffic flow, and the fact that the appliance will need
a chimney and chimney connector. It is a good idea
to plan your installation on paper, using exact mea-
surements for clearances and floor protection, before
actually beginning the installation. When installing on
a combustible floor, the optional bottom heat shield
must be installed along with using proper floor protec-
tion material. See page 12 for details.
Maintain specified vent clearance to combustible
Maintain specified vent clearance to combustible
requirements listed by the vent manufacturers instruc-
tions and all clearance to combustibles listed in this
manual.
Check with your local building code agency before
Check with your local building code agency before
you begin your installation. Be sure local codes do not
supersede UL specifications and always obtain the
required permit so that insurance protection benefits
cannot be unexpectedly cancelled. If any assistance
is required during installation, please contact your
dealer.
We recommend that a qualified building inspector and
We recommend that a qualified building inspector and
your insurance company representative review your
plans before and after the installation.
Be sure to provide a source of fresh air to the room
Be sure to provide a source of fresh air to the room
or directly to the appliance. Make-up air is needed to
replace what the chimney draws away through the
appliance.
CAuTION
• dO NOT CONNECT THIs uNIT TO A CHIMNEy fLuE
sERvICING ANOTHER APPLIANCE.
• dO NOT CONNECT TO ANy fORCEd AIR dIsTRIBu-
TION duCT OR sysTEM.
B. fire safety
Maintain the designated clearances to combustibles.
Insulation must not touch the chimney. You must
maintain the designated air space around the chim-
ney. This space around a chimney is necessary to
allow natural heat removal from the area. Insulation
in this space will cause a heat buildup, which may
ignite wood framing.
NOTE: Clearances may only
be reduced by means approved by the regulatory
authority having jurisdiction.
To provide reasonable fire safety, the following should
be given serious consideration:
1. Install at least one smoke detector on each floor
of your home. Detectors should be located away
from the heating appliance and close to sleeping
areas. Follow the smoke detector manufacturer's
placement and installation instructions, and be
sure to maintain regularly.
2. A conveniently located Class A fire extinguisher
to contend with small fires resulting from burning
embers.
3. A practiced evacuation plan, consisting of at least
two escape routes.
4. A plan to deal with a chimney fire as follows:
In the event of a chimney fire:
a. Evacuate the house immediately.
b. Notify Fire Department.
c. Never apply water to a suspected chimney fire.
Serious damage could occur.
WARNING
fIRE HAzARd
• dO NOT OPERATE APPLIANCE
BEfORE REAdING ANd uNdER-
sTANdING THE OPERATING
INsTRuCTIONs.
• fAILuRE TO OPERATE PROPERLy
MAy CAusE A HOusE fIRE.