Oakleaf Woodburning stove
A. design, Installation & Location 
Considerations
3
 
Getting started
1.  Appliance Location
Consideration must be given to safety, convenience, 
traffic flow, and the fact that the appliance will need 
a chimney and chimney connector. It is a good idea 
to plan your installation on paper, using exact mea-
surements for clearances and floor protection, before 
actually beginning the installation. When installing on 
a combustible floor, the optional bottom heat shield 
must be installed along with using proper floor protec-
tion material. See page 12 for details.
Maintain specified vent clearance to combustible 
requirements listed by the vent manufacturers instruc-
tions and all clearance to combustibles listed in this 
manual.
Check with your local building code agency before 
you begin your installation. Be sure local codes do not 
supersede UL specifications and always obtain the 
required permit so that insurance protection benefits 
cannot be unexpectedly cancelled. If any assistance 
is required during installation, please contact your 
dealer.
We recommend that a qualified building inspector and 
your insurance company representative review your 
plans before and after the installation.
Be sure to provide a source of fresh air to the room 
or directly to the appliance. Make-up air is needed to 
replace what the chimney draws away through the 
appliance.
CAuTION
•  dO NOT CONNECT THIs uNIT TO A CHIMNEy fLuE 
sERvICING ANOTHER APPLIANCE.
•  dO NOT CONNECT TO ANy fORCEd AIR dIsTRIBu-
TION duCT OR sysTEM.
B. fire safety
Maintain the designated clearances to combustibles. 
Insulation must not touch the chimney. You must 
maintain the designated air space around the chim-
ney. This space around a chimney is necessary to 
allow natural heat removal from the area. Insulation 
in this space will cause a heat buildup, which may 
ignite wood framing. 
NOTE: Clearances may only 
be reduced by means approved by the regulatory 
authority having jurisdiction.
To provide reasonable fire safety, the following should 
be given serious consideration:
1.  Install at least one smoke detector on each floor 
of your home. Detectors should be located away 
from the heating appliance and close to sleeping 
areas. Follow the smoke detector manufacturer's 
placement and installation instructions, and be 
sure to maintain regularly.
2.  A conveniently located Class A fire extinguisher 
to contend with small fires resulting from burning 
embers.
3.  A practiced evacuation plan, consisting of at least 
two escape routes.
4.  A plan to deal with a chimney fire as follows:
      In the event of a chimney fire:
      a. Evacuate the house immediately.
      b. Notify Fire Department.
      c. Never apply water to a suspected chimney fire.  
          Serious damage could occur.
WARNING
fIRE HAzARd
•  dO NOT OPERATE APPLIANCE 
BEfORE REAdING ANd uNdER-
sTANdING THE OPERATING 
INsTRuCTIONs.
•  fAILuRE TO OPERATE PROPERLy 
MAy CAusE A HOusE fIRE.