4.  Install the two hinges to the front panel of the dryer using  
4 screws. Use the non-slotted side to attach the hinge  
to the front panel.
5.
  
Install screws in top hinge holes in the door. Do not tighten 
screws. Leave approximately 1/4" (5 mm) of screw exposed
.
6.  Hang door by placing screw heads into top slotted holes of 
hinges and slide door down. Align bottom screw holes in hinge 
and door. Install two bottom screws. Tighten all hinge screws.
7.  Close door to engage door strike.
TROUBLESHOOTINg
DRYER oPERATion
Dryer will not run
Has a household fuse blown, or has a circuit breaker 
 
tripped? 
There may be two household fuses or circuit breakers  
for the dryer. Check that both fuses are intact and tight,  
or that both circuit breakers have not tripped. Replace  
the fuse or reset the circuit breaker. If the problem  
continues, call an electrician.
is the correct power supply available? 
 
Electric dryers require a 240-volt power supply. Check  
with a qualified electrician.
Was a regular fuse used? 
 
Use a time-delay fuse.
no heat
Has a household fuse blown, or has a circuit breaker 
 
tripped? 
The drum may be turning, but you may not have heat. Elelctric 
dryers use two household fuses or circuit breakers.Replace 
the fuse or reset the circuit breaker. If the problem  
continues, call an electrician.
Dryer displaying code message
"PF" (power failure), check the following: 
 
Was the drying cycle interrupted by a power failure? 
Press and hold START/PAUSE to restart the dryer.
“l2” Diagnostic Code (low or no line voltage condition):
 
 
The drum will turn, but there may be a problem with your 
home power supply keeping the dryer’s heater from turning 
on. The dryer will continue to run when this diagnostic code  
is present. 
 
Press any key to clear the code from the display and return  
to the estimated time remaining. 
 
   Try the following:  
Check to see if a household fuse has blown or circuit breaker 
has tripped. Electric dryers use two household fuses or 
breakers. Replace the fuse or reset the circuit breaker. 
 
Confirm the power cord is properly installed. Refer to 
“Electrical Connection” for details. 
 
Select a Timed Dry heated cycle, and restart the dryer. 
 
If the message persists, consult a qualified electrician.
“AF” (low airflow condition): 
 
The dryer will continue to run when this diagnostic code is 
present. Press any key to clear the code from the display and 
return to the estimated time remaining. 
 
  Try the following:  
Clean lint screen. 
 
Check to see if the vent run from the dryer to the wall is free 
of lint and debris. 
 
Confirm the exterior vent exhaust hood is free of lint and 
debris. 
 
Confirm your vent system falls within the recommended run 
length and number of elbows for the type of vent you are 
using. Refer to “Plan Vent System” for details.