     To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical 
supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit 
breaker is recommended. Connect to an individual branch circuit.
DRAIN SYSTEM
Drain system can be installed using a floor drain, wall standpipe,  
floor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum 
carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe 
must be at least 39" (990 mm) high; install no higher than 96"  
(2.4 m) from bottom of washer/dryer. If you must install higher 
than 96" (2.4 m), you will need a sump pump system.
Wall standpipe drain system
See requirements for floor standpipe drain system.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number 
285834), 2 Connector Kits (Part Number 285385), and an  
Extension Drain Hose (Part Number 285863) that may be  
purchased separately. See “Use and Care Guide” for ordering 
details. Minimum siphon break: 28" (710 mm) from bottom of 
washer/dryer. (Additional hoses may be needed.)
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be  
at least 39" (990 mm) above floor; install no higher than 96"  
(2.4 m) from bottom of washer/dryer. 
IMPORTANT: To avoid siphoning, no more than 4.5" (113 mm) 
of drain hose should be inside standpipe or below the top of 
wash tub. Secure drain hose with shipping strap.
ELECTRICAL REQUIREMENTS
VENTING REQUIREMENTS
Recommended Styles:
Acceptable Style:
Louvered hood
 Box hood
Angled hood
Number of 
90° turns  
or elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
2
0
Rigid metal
Rigid metal
Rigid metal
37 ft. (11.3 m)
32 ft. (9.7 m)
24 ft. (7.3 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
19 ft. (5.8 m)
The “Vent System Chart” provides venting requirements that 
will help achieve best drying performance.
NOTE: 
Side exhaust installations have a 90º turn inside the dryer.  
To determine maximum exhaust length, add one 90º turn to the chart.
E
xhaust venting: Exhaust your dryer to the outside. 4" (102 mm) 
diameter vent is required. Rigid or flexible metal exhaust vent 
must be used. Do not use plastic or metal foil vet. Exhaust hood 
must be at least 12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
Vent System Chart