Whirlpool oortable spa 用户手册

下载
页码 43
www.clearcreekspas.com 
 
www.clearcreekspas.com 
INSTALLATION 
 
Electrical Precautions 
 
CAUTION 
Do  not  apply  electrical  power  to  the  spa  unless  it  is 
filled  with  water  to  the  normal  water  level,  which  is 
approximately 7" below the spa rim.  (See location of 
water level indicator on face of skimmer on page 6.)  If 
the spa’s motor/pumps are actuated when there is not 
sufficient water in the unit, the circulation pumps could 
be irreparably damaged.  In addition to damaging the 
unit,  operating  the  unit  with  insufficient  water  could 
cause a fire.
 
 
Do not locate lighting fixtures directly above the spa; 
lighting and electrical receptacles must be located at least 
5 ft (1.5m) from the spa.  Lighting located between  and 5 
ft (1.5m) and 10 ft (3m) from the spa must be on a circuit 
protected by a ELCB.  (See National Electrical Code 680- 
6). 
 
 
Do  not  use  electrically  connected  devices,  such  as 
television, radio, telephones, stereo speakers, lights or 
cooking devices within 5 ft (3m) of the spa when the spa 
is being used. 
 
All fixed metal objects located within 5 ft (1.5m) of the 
spa, such as fence posts, railings, door frames, green- 
house structures, gutters, etc., must be attached to the 
bonding bar on the outside of the spa System Control 
Module using #8 solid copper wire.  With #8 solid copper 
wire,  bond  the  spa  to  the  house  electrical  panel  or 
approved local earth electrode. 
 
An approved earth electrode may be an 8 ft. long 
earth rod, a plate electrode, or a buried metal water 
pipe with at least 10 ft. of buried pipe.  Check your local 
building code for requirements. Bonding lugs are avail- 
able  at  your  local  electrical  supply  store.  (Bond  bar 
location is shown on page 5.) 
 
 
Outdoor Installation 
If you install the spa outdoors, we recommend that you 
provide a concrete pad for it to rest on.  To do this, construct 
forms for a 8' x 8' x 4" thick level pad. 
 
Install a #10 gauge wire mesh approximately 6" x 6" steel 
reinforced grid.  Attach a #8 solid copper wire to the grid with 
a ground clamp.  This wire should be long enough to reach 
the bond bar on the spa System Control Module (min 36"), 
but should not be located under the base of the spa.  Then 
pour the concrete pad. 
Drainage 
Whether you install your spa indoors or outdoors,  you 
can drain it completely by attaching a garden hose to the 
drain valve located on the suction tee of the spa.  Simply run 
the hose to the house sewer line or drain field and open the 
drain valve. 
 
Make  sure  the  area  surrounding  the  spa  has  good 
drainage to keep water from collecting at the base of the 
 
 
 
 
spa—especially near the equipment area.  If drainage is 
poor,  install  a  drain  line  and/or  gravel  drain  field  (see 
illustration below). 
 
Indoor Installations 
Water which splashes on the floor during use of the 
spa may cause a walking hazard and/or structural dam- 
age unless good drainage is provided and proper water- 
proof building materials are used in the area surrounding 
and beneath the spa.  Take into consideration, also, the 
high room humidity which will exist due to high spa water 
temperatures.  Providing natural or forced ventilation of 
the room will help maintain comfort and minimize mois- 
ture damage to the building.  Jacuzzi Whirlpool Bath is 
not responsible for damages resulting from excess mois- 
ture or water spillage. Consult an architect or engineer for 
aid in designing your indoor installation. 
 
 
 
SUPPORT AND DRAINAGE 
 
#8 BOND WIRE 
(TO HOUSE ELECTRICAL 
PANEL OR LOCAL BOND) 
 
WIRE MES H GRID 
 
TO BOND BAR 
 
 
 
 
8' x 8' x 4"  THICK 
CONCRETE PAD