Enviro EC-061 用户手册

下载
页码 3
Freestanding Direct 
Vent Kit With Coupler
 
KIT COMPONENTS:
Quantity Description
Quantity Description
1
Horizontal direct vent termination cap
1
Ø65⁄8” (17 cm) 90° elbow
2
Flue collar adapters (only one used)
4
Wire spacers
4
T-20 Torx screws
3
Decorative rings
1
Wall thimble
1
4 oz tube RTV silicone
1
Inside finish trim collar
20
9
/
16
” tech screws
1
5’  (190 cm) length of Ø4” (10 cm) double walled flex pipe
8
11⁄2” wood screws
2
24” (61 cm) section of Ø65⁄8” (17 cm) straight pipe
1
Vinyl siding deflector
Please  ensure  that  all  components  are  supplied  with  this  kit.  If  components  are  missing  or  have 
been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if 
components are missing or damaged.
INSTALLATION INSTRUCTIONS:
1. Decide on a location for the unit that will meet any or all local code requirements. Refer to the sections 
in your owner’s manual on where to locating your stove, planning your installation and clearances to 
combustibles.
2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing 
pipes are in the way of the venting system as it passes through the wall. If obstructions are found in 
the wall it may be required to adjust the location of the appliance.
3. Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non-crimped 
end on the unit 
4. Install the 90° elbow onto the vertical pipe on the stove pointing in the 
direction that the vent will exit the structure. 
5. Project a level line from the center point of the elbow. Using this center 
point, scribe a 10” (25.4 cm) hole or square on the wall . Cut the hole 
out on both the interior and exterior wall surface. 
6. Frame the hole as shown in Figure 1. 
7.  Install  the  wall  thimble  and  secure  the  thimble  to  the  inner  wall 
surface.
8. With the appliance still in place install the 24” (61 cm) horizontal section 
on the elbow and let this section of pipe protrude through the exterior 
surface. Mark the pipe so that when it is cut it will be flush with the 
exterior wall.
9. Dismantle the outer pipe sections.
Figure 1
Please read and understand these instructions before installing. Failure to follow 
these instructions carefully could cause property damage or personal injury.
���
�������
���
�������