10
Bradyprinter 200M-e and 200M-e 300 User’s Guide
3RVLWLRQLQJWKH0HGLD6HQVRUV
The correct positioning of the media sensors is important — it can make 
the difference between a perfect label and a call to Technical Support!
7UDQVPLVVLYH6HQVRU
The web or gap sensor (transmissive sensor) detects the gap between 
labels.
The transmissive sensor actually consists of two sections:  a light source 
(the lower media sensor) and a light sensor (the upper media sensor).  The 
media passes between the two.
The upper media sensor must be positioned:
• Directly over the hole or notch, or
• Anywhere along the width of the media if there is a gap between labels.
NOTE:  If you are using continuous media, position the upper 
media sensor over the media so that the printer can detect an       
out-of-paper condition.