Wasp Bar Code DuraLine WLS 8400 ER/FZ Series 用户手册

下载
页码 4
Reset Defaults
TROUBLESHOOTING
SCANNER PROGRAMMING BAR CODES
BEEPER  INDICATIONS
Scanner not working
Check system power;
ensure power supply,
if required, is connected
No power to scanner
Ensure that correct
interface cable is used
Incorrect interface
cable used
Check for loose
cableconnections
Interface/power
cables are loose
Standard Use
Power up
Low/medium/high beep
Bar code decoded [if
decode beeper enabled]
Short high beep
Transmission error
detected; data is ignored
4 long low beeps
LED  INDICATIONS
Scanner is on and
ready to scan, or no
power to scanner
Off
Bar code is 
successfully decoded
Green
Transmission error
Red
Parameter Menu Scanning
Successful parameter
setting
High/low/high/low beep
Correct programming
sequence performed
High/low beep
Incorrect programming
sequence or Cancel bar
code scanned
Low/high beep
Scanner not decoding bar code
Ensure scanner is
programmed to read type
of bar code beingscanned
Scanner not programmed
for bar code type
Ensure bar code is not
defaced; try scanning
test bar code of same
bar code type
Bar code unreadable
Move scanner
closer to or further
from bar code
Distance between
scanner and bar
code incorrect
Scanner decoding bar code, but data not transmitting to host
Check scanner host parameters 
or edit options
Scanner not programmed for
correct host interface
Check for loose cable connections
Interface cable is loose
Scanned data incorrectly displayed on host
Check scanner host parameters or edit options
Scanner not programmed for correct host interface
USB Host Types
Keyboard Wedge Host Types
<Enter>
<Tab>
Set Postamble
Erase All Rules
Save All Rules
Begin New Rules
Send All Data
QUICK START GUIDE
w w w . w a s p b a r c o d e . c o m
Start Here if you have a USB scanner
Enter
Choose a Postamble
Tab
Start Here if you have a keyboard wedge scanner
1
1
2
3
4
5
If you do not need a Postamble scan      Erase All Rules only.
NOTE
©2005 Wasp Technologies. All rights reserved.
Wasp reserves the right to make changes to any product to improve reliability, function, or design. Wasp does not assume any product liability arising out of, or in connection with, the
application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent,
covering or relating to any combination, system, apparatus, machine, material, method, or process in which Wasp products might be used. An implied license exists only for equipment,
circuits, and subsystems contained in Wasp products. Wasp and the Wasp logo are registered trademarks of Wasp Technologies. Other product names mentioned in this manual may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Wasp Technologies, 1400 10th Street, Plano, TX 75074, www.waspbarcode.com