WhisperKool XLT SERIES XLT 3000 用户手册

下载
页码 36
Page 8
XLT 020111
Cutting the Hole for the WhisperKOOL Unit 
Tools Needed 
Sizing the Unit to the Room 
• Using a level and a pencil, mark a horizontal line on 
the wall between the two studs, approximately 1.25 
inches  (or  as  close  as  possible  if  more  than  1.25”) 
from the ceiling. 
• Using a ruler or measuring tape, measure 16 inches 
down (22.75” for the 6000 and 8000 models), and 
mark  another  horizontal  line  parallel  to  the  first 
one. 
Locate the desired installation location. Using a stud finder, locate two adjacent studs in the walls, and mark them 
with vertical lines.
• Using a saw, cut along the uppermost horizontal line 
until your saw reaches the stud. Turn the saw around, 
inserting it into the cut you have just made, and cut 
toward  the  opposite  stud  so  that  you  have  a  clean 
horizontal cut between the two studs. Be careful not 
to  cut  into  the  studs  themselves.  Now  make  the 
second horizontal cut from stud to stud on the line 16 
inches  below  the  first  cut  (22.75”  for  the  6000  and 
8000 models).
Hammer
Mark the horizontal lines with a level
Cut horizontal lines from stud to stud.
Saw
Screwdriver
Level
MODEL
 
 
AMPS 
AMPS 
PRODUCT DIMENSIONS 
ROOM SIZE
 
 
(starting)  (running) 
(H x W x D) 
(cubic feet)
WK 1600
 
 
28.32 
4.5 
15.75" x 14.25" x 17" 
300
WK 3000
 
 
30.00 
15.75" x 14.25" x 17" 
650
WK 4200
 
 
32.00 
15.75" x 14.25" x 17" 
1000
WK 6000
 
 
36.00 
9.5 
22.5" x 14.25" x 21.25" 
1500
WK 8000
 
 
36.00 
10 
22.5" x 14.25" x 21.25" 
2000